摘要 离心式压缩机中间冷却器结垢沉积速度快,清洗频率高,分析认为冷却水流量不足并且分配不均是产生污垢沉积的主要原因,水质控制与管理也是不可忽视的因素,通过水量调整、规范水质管理措施后基本解决了清洗频率高的问题。 There are some problems in the intercooler of centrifugal compressor, for ex- ample rapid scale deposition speed and high cleaning frequency. The analysis results indicate that the main reason of scale deposition is low cooling water flow rate and uneven distribu- tion of cooling water. And water quality control is an important factor that should not be no- glected. The problem of high cleaning frequency has been basically solved by ter flow rate and standardizing water quality management. regulating wa-
出处 《冶金动力》 2013年第3期66-69,共4页 Metallurgical Power
关键词 离心式压缩机 冷却水处理 失效分析 centrifugal compressor cooling water treatment failure analysis
  • 相关文献

参考文献3

  • 1黄其励等.电力工程师手册[M].北京:中国电力出版社,2001
  • 2锅炉房实用设计手册编写组.锅炉房实用设计手册(第二版)[M].北京:机械工业出版社,2001.
  • 3邝生鲁.化学工程师技术全书[M].北京:化学工业出版社,2002..