期刊文献+

西山玉门河小区四区室内消防系统设计

The design of four district indoor fire fighting system of Xishan Yumen river area
下载PDF
导出
摘要 介绍了居住小区西山玉门河小区四区的消防给水系统设计,结合地形和建筑规划布置,详细说明了小区消防系统中的消防水池及消防水箱间的设计;消火栓系统采用竖向分高低区的供水方式;消火栓给水系统和自动喷水灭火系统的供水干管均敷设在地下车库内呈环状布置并向各单体引出相应的消防供水管道。 This paper introduced the fire fighting water supply system design of four district of Xishan Yumen river residential area, combining with terrain and architecture planning, introduced in detail the fire fighting pool and high fire fighting water tank design in area fire fighting system, the fire hydrant system adopted the water supply side type of vertical level area, the system of water supply pipe laying into the ring arrangement in the underground garage and the monomer leads to fire water supply pipe corresponding fire hydrant system and automatic sprinkler.
作者 原妙丽
出处 《山西建筑》 2013年第10期111-113,共3页 Shanxi Architecture
关键词 消防水池 高位消防水箱 消火栓给水系统 自动喷水灭火系统 fire fighting pool high fire fighting water tank fire hydrant water supply system automatic sprinkler extinguishment system
  • 相关文献

参考文献3

  • 1GB 50016-2006,建筑设计防火规范[S].
  • 2GB 50045-95,高层民用建筑设计防火规范(2005年版)[S].
  • 3GB 50084-2001自动喷水灭火系统设计规范(2005年版)[S].