高加管板与封头过渡倒角对管板应力分布的影响 被引量:1

The Influence for the Tube Sheet Stress from the Filleting of the Tube Sheet of U-type Horizontal High Pressure Feed-water Heater
下载PDF
导出
摘要 U型管卧式高压给水加热器管板水侧边缘存在应力集中现象。为减少应力集中对管板的损伤,降低制造厂的生产成本,通过研究管板(与水室封头连接侧)倒角半径R的取值,寻找到合适的R,从而使高压给水加热器管板水侧边缘应力分布趋于合理。 The edge of the tube sheet on the tube side of the U -type horizontal high pressure feed - water heater exists stress concentration. In order to decrease the damage for the tube sheet from the stress concentration and reduce manufacture cost,searching appropriate R through studying filleting R span of the tube sheet (on the side of connecting with the water chamber) , thus the stress will be- come more reasonable of the edge of the tube sheet on the tube side.
出处 《锅炉制造》 2013年第2期55-56,60,共3页 Boiler Manufacturing
关键词 U型管卧式高压给水加热器 管板 倒角 应力分布 U- type horizontal high pressure feed -water heater tube sheet Filleting stress distri-bution
  • 相关文献

参考文献3

  • 1GB150-1998.钢制压力容器[S].[S].,..
  • 2GB151-1999.管壳式换热器[S].[S].北京:国家质量技术监督局,1999..
  • 3李建国.压力容器设计的力学基础及其标准应用[M].北京:机械工业出版社,2005年第二次印刷本..