摘要 利用HACH公司的DR2800型COD反应器,用自制药剂代替HACH专用药剂,确立了高、低两种量程COD浓度的分光光度测定法。COD在100 mg·L-1至1 000 mg·L-1时,测定波长为600 nm,方法检出限为12 mg·L-1。COD在10 mg·L-1至100 mg·L-1时,测定波长为440 nm,方法检出限为8 mg·L-1。加标回收率在90%~110%之间。测定费用低,准确度和精密度高,测定结果令人满意。 Spectrophotometry for determination of COD with high/low two ranges can be achieved by using HACH DR2800 COD detector with self- make reagents instead of the special reagents of HCAH. The detecting wave- length is 600 nm ranged from 100 mg · L-1 to 1 000 mg · L-1. Detection limit of method is 12 mg · L-1. The detec- ting wavelength is 440 nm ranged from 10 mg · L-· to 80 mg · L-1. Detection limit of method is 8 mg · L-1. The re- covery rate of samples is between 90% · 110%. The results are satisfied because of the low cost, high accuracy and precision.
出处 《化工时刊》 CAS 2013年第2期18-20,共3页 Chemical Industry Times
关键词 化学需氧量 快速测定 分光光度法 chemical oxygen demand fast determination spectrophotometry
  • 相关文献

参考文献5

二级参考文献16

  • 1姚淑华,石中亮,宋守志,陈桂英.用开管法快速测定废水的COD[J].化工环保,2004,24(2):138-140. 被引量:17
  • 2沈歈忼,陈立波.COD快速开管测定法研究[J].环境工程,1994,12(1):40-42. 被引量:37
  • 3韦利杭.化学需氧量快速测定法的研究[J].环境污染与防治,1995,17(3):38-41. 被引量:38
  • 4赵亚乾.Cl^-、NH_3和H_20_2对COD测定的影响[J].上海环境科学,1995,14(8):32-34. 被引量:24
  • 5国家环保局.水和废水监测分析方法[M].北京:中国环境科学出版社,1989.260-263.
  • 6国家技术监督局 国家环境保护局.水质分析方法国家标准汇编[M].北京:中国标准出版社,1998.280.
  • 7尹洧.水和废水监测分析方法指南:上册[M].北京:中国环境科学出版社.1990:225.
  • 8水利部水利水电规划设计总院.SL368-2006再生水水质标准[S].北京:中国水利水电出版社,2007.
  • 9国家环境保护总局.GB11914-89水质化学需氧量的测定重铬酸盐法[S].北京:中国环境科学出版社,2002.
  • 10国家环境保护总局.HJ/T11399-2007水质化学需氧量的测定快速消解分光光度法[S].北京:中国环境科学出版社,2008.