期刊文献+

脉冲冲洗器在四肢清创术中的应用效果 被引量:6

Application of Pulsed Lavage in Debridement
下载PDF
导出
摘要 目的探讨脉冲冲洗器在四肢清创术中的临床应用效果。方法48例四肢开放性损伤患者中采用脉冲冲洗器清创18例(观察组),采用常规人工倾倒冲洗法清创30例(对照组)。比较2组清创时间、冲洗液用量、二次清创率、术后拆线时间及冲洗费用,观察2组伤口愈合情况及不良反应发生情况。结果脉冲冲洗器清创较人工倾倒冲洗法冲洗液用量少、二次清创率低(P<0.05),且术后伤口愈合佳(P<0.05),但冲洗费用明显增高(P<0.05)。2组清创时间、术后拆线时间比较,差异无统计学意义(P>0.05)。结论脉冲冲洗器在清创术中应用效果良好,在患者经济条件允许的情况下,推荐使用。 Objective To investigate the clinical efficacy of pulsed lavage in debridement.Methods Forty-eight patients with open extremity injuries were assigned to receive debridement with either pulsed lavage(observation group,n=18)or artificial dumping rinse(control group,n=30).Debridement time,amount of flushing water,rate of the second debridement,time of suture removal,washing costs,wound healing and adverse reactions were compared between the two groups.Results The observation group had lower second debridement rate,less amount of flushing water,higher washing costs and better wound healing than the control group(P0.05).But no significant differences in debri-dement time and suture removal time were found between the two groups(P0.05).Conclusion The disposable pulsed lavage device is effective in debridement and should be recommended in patients who can pay the costs.
出处 《实用临床医学(江西)》 CAS 2013年第1期38-39,共2页 Practical Clinical Medicine
关键词 脉冲冲洗器 人工倾倒冲洗 清创术 四肢开放性损伤 pulsed lavage artificial dumping rinse debridement open extremity injuries
  • 相关文献

参考文献3

二级参考文献13

  • 1朱通伯.处理开放性骨折及关节创伤的新观点[J].中华骨科杂志,1995,15(6):393-396. 被引量:77
  • 2宣跃云 汪世清.新型实用清创车的研制[J].医疗设备,1997,12:9-9.
  • 3曹斌,陆叙林,王化竹,翟振华,樊建政.自制自动喷淋清创车的临床应用[J].山东医药,1997,37(1):20-20. 被引量:2
  • 4Haimi S, Wahlman M, Mannila M, et al. Pulse-lavage washing is an effective method for defatting of morselized allograft bone in the op- erating theater. Acta Orthop, 2008, 79: 94-97.
  • 5Granick MS, Tenenhaus M, Knox KR, et al. Comparison of wound irrigation and tangential hydrodissection in bacterial clearance of contaminated wounds: results of a randomized, controlled clinical study. Ostomy Wound Manage, 2007, 53: 64-66, 68-70, 72.
  • 6Clarius M, Hauck C, Seeger JB, et al. Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicom- partmental knee arthroplasty: pulsed lavage versus syringe lavage, lnt Orthop, 2009, 33: 1585-1590.
  • 7Zalavras CG, Marcus RE, Levin LS, et al. Management of open fractures and subsequent complications. J Bone Joint Surg(Am), 2007, 89: 884-895.
  • 8Fletcher N, Sofianos D, Berkes MB, et al. Prevention of periopera- tive infection. J Bone Joint Surg(Am), 2007, 89: 1605-1618.
  • 9梁廷波.清创术的正确实施[J].中国实用外科杂志,2008,28(1):35-37. 被引量:18
  • 10张波,孔宪炳,刘良明,廖刚.数字式多功能外伤清洗机应用的实验研究[J].重庆医科大学学报,2008,33(2):213-215. 被引量:4

共引文献13

同被引文献65

引证文献6

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部