摘要
简要介绍了数字地震台网地震监测能力的计算方法,结合彭水水库地震台网监测要求与设计监测能力,利用台网2008年9月至2011年12月期间的936个ML1.5级以下地震记录数据,检验和分析了台网的实际监测能力,结果表明,台网的实际监测能力达到设计要求。
This article discusses the calculation method for the monitoring ability test of the digital seismic network. According to monitoring requirements and design of the Pengshui hydropower station reservoir seismic network's mo- nitoring ability,we use 936 earthquake recordings September,from 2008 to December 2011, to test analyze the real monitoring ability of the seismic which is below ML1.5 recorded by the seismic network during the monitoring ability of this seismic network. We examine and network. The result shows that the real monitoring ability of the seismic network achieved the goal of our original design.
出处
《四川地震》
2013年第1期26-30,共5页
Earthquake Research in Sichuan
关键词
彭水水库地震台网
台址背景噪声
监测能力
Pengshui reservoir seismic network
site background noise
monitoring capability