摘要
某电厂燃气轮机机组在检修后启动并网运行过程中出现"透平一级后轮间温度高报警"这一现象,通过对透平高温部件的冷却过程和轮间热电偶的布置情况进行分析,对可能的故障原因采取了一些处理方法并提出了预防措施,从而确保燃气轮机组的安全运行。
A gas turbine temperature alarmed in high level between the rear wheels in repair after the start of grid-connected operation process. High temperature parts of turbine the cooling process and the wheel thermocouple arrangement were analyzed, the possible fault causes were taken some treating methods and preventive measures were proposed, in order to to ensure the safe operation of gas turbine unit.
出处
《燃气轮机技术》
2013年第1期63-66,共4页
Gas Turbine Technology