摘要
根据文献介绍的质偏测量方法及计算公式,推导出误差的计算公式.根据误差计算公式给出这两种方法的精度对比,为减少误差,对测试仪器进行了合理的结构分析以及改进方案。指出文献给出的某些结论性意见缺乏理论依据,不宜作为测试方法的选择和精度比较的依据。
According to the literature introduction of calculation formula and measurement methods of centroidal deviation, the accurate error formula was derived. Based on the error formula, the precision contrast of two methods was given. In order to reduce errors, reasonable structure and the improvement plan of the test instrument were put forward. It is pointed out that some conclusions of literature lacks theoretical evidence, should not use as the choice of test method and the basis of precision contrast.
出处
《兵器材料科学与工程》
CAS
CSCD
北大核心
2013年第2期20-24,共5页
Ordnance Material Science and Engineering
关键词
精度分析
测重法
质偏
误差
accuracy analysis
weight measurement method
centroidal deviation
error