摘要
分析了TRT(Topgas Recovery Turbine高炉煤气余压发电装置)无刷励磁发电机旋转整流盘常见的故障。针对TRT无刷励磁发电机运行环境特点及其具体运行情况,对产生故障的原因进行了分析,并提出消除此类故障的措施。、
The common faults for the rotating rectifier dish in TRT (Top gas Recovery Turbine) brush- less excitation generator are analyzed, Aiming at the running environment characteristics and specific running status of TRT brushless excitation generator, the analysis on the reasons causing failures is ear- fled out, and the measures to eliminate this kind of failures are put forward.
出处
《莱钢科技》
2013年第1期33-34,37,共3页
Laigang Science & Technology
关键词
TRT
无刷励磁发电机
旋转整流盘
TRT
brushless excitation generator
rotating rectifier dish