期刊文献+

HIFU辐照离体牛眼晶状体致凝固性坏死出现时间与空化关系的定性研究 被引量:4

Qualitative research of the relationship between occurrence time of coagulation necrosis and cavitation during HIFU exposures
下载PDF
导出
摘要 目的:研究高强度聚焦超声(high intensity focused ultrasound,HIFU)辐照离体牛眼睛所致热凝固性坏死出现的时间与空化的关系。方法:使用自制支架固定牛眼晶状体,使用不同辐照参数(100w-6s、200w-3s、300w-2s、600w-1s)的HIFU辐照离体牛眼晶状体,辐照过程中使用高速摄影系统摄录晶状体中凝固性坏死的形成过程,并用被动空化检测(passive cavitation detection,PCD)系统对辐照中牛眼晶状体中发出的声散射信号(acoustic emissions)进行检测后在LabVIEW开发平台上编程对其量化分析。辐照结束后,观察HIFU致牛眼晶状体中的损伤形态。结果:HIFU辐照牛眼晶状体,都产生了凝固性坏死,且出现的时间不同。100、200、300和600W功率的HIFU辐照中凝固性坏死出现的平均时间分别为1.921、1.109、0.627和0.240 s。辐照结束后,肉眼观察可见牛眼晶状体中形成的凝固性坏死大小和形态类似。除100W外,其余功率的HIFU辐照过程中均观察到了空化的发生,且辐照功率越大,空化越剧烈。结论:HIFU辐照中空化的发生影响凝固性坏死的产生,且空化越剧烈,凝固性坏死形成时间越短。 Objective: To study the relationship between currence time of coagulation necrosis and cavitation during HIFU exposures qualitatively. Methods: The bovine lens were exposed to HIFU with various parameters (100w- 6s, 200w- 3s, 300w- 2s and 600w- Is) after fixed using a homemade bracket. The high- speed photography device was used to record the formation process of coagulation necrosis in the bovine lens. Acoustic emissions were al~ detected by a passive cavitation detection (PCD) system and then processed with a program which was written on LabVIEW previously. The lens after irradiations were observed and photographed. Results: Coagulation necrosis were observed in all bovine lens during HIFU exposures while the occurrence time differentiated. The mean appear time of coagulation necrosis in bovine lens was 1.921, 1.109, 0.627and 0.240 s respectively after HIFU with the acoustic powers of 100, 200, 300 mad 600 W. Under naked eye, the volumes and shapes of lesions were similar after all exposures with different powers and times. Cavitation behaviors were detected during 200, 300 and 600 W acoustic powers HIFU irradiations, and the greater power, the more severe cavitation. Conclusions: Coagulation necrosis in the bovine lens were affected by cavitation during HIFU exposures, and the more severe cavitation, the shorter the ~currence time of coagulation necrosis.
出处 《激光杂志》 CAS CSCD 北大核心 2013年第2期64-66,共3页 Laser Journal
基金 国家重点基础研究发展计划-973计划(2011CB707902) 国家自然科学基金重点项目(30830040) 国家自然科学基金面上项目(30970827)
关键词 HIFU 凝固性坏死 空化 晶状体 热效应 HIFU coagulation necrosis cavitation lens thermal. ..
  • 相关文献

参考文献10

  • 1Illing RO, Kennedy JE, Wu F, et al. The safety and feasibility of extracorporeal high - intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population [ J ]. British Journal of Cancer,2005,93(8) : 890 -895.
  • 2Wu F, Wang ZB, Zhu H, et al. Feasibility of US- guided high - intensity focused ultrasound treatment in patients with advanced pancreatic cancer: initial experience [ J]. Radiology, 2005,236 ( 3 ) : 1034- 1040.
  • 3Wu F, Wang ZB, Chen WZ, et al. Advanced hepatocellular carcinoma: treatment with high - intensity focused ultrasound ablation combined with transcatheter arterial embolization [ J ]. Radiology, 2005,235 (2) : 659 - 667.
  • 4Zhang L, Chen WZ, Liu YJ, et al. Feasibility of magnetic resonance imaging- guided high intensity focused ultrasound therapy for ablating uterine fibroids in patients with bowel lies anterior to uterus [J]. European Journal of Radiology,2010,73(2) :396 - 403.
  • 5Melodelima D, Chapelon J Y,Theillere Y, et al. Combination of themml and cavitation efects to generate deep lesions with an endocavitary applicator using a plane transducer: ex vivo studies[J]. Ultrasound in Medicine and Bioloav. 2004.30( 1 ) : 7103 - 111.
  • 6刘春梅,陈锦云,柯丹,李崇雁,徐杰,雷令,李发琪.脉冲高强度聚焦超声联合微泡非热损伤兔肝VX2移植瘤的病理观察[J].中国超声医学杂志,2007,23(11):806-809. 被引量:9
  • 7Kennedy JE,Ter Haar G, Cranston D. High intensity focused ultrasound: surgery of the future? [J]. British Journal of Radiology,2003,76(909) : 590 - 599.
  • 8Yang X, Roy RA, Holt RG. Bubble dynamics and size distributions during focused ultrasound insonation [ J ]. Journal of the Acoustical Society of America, 2004,116(6) : 3423 - 3431.
  • 9McLanghlan J, Rivens I, Leighton T, et al. A study of bubble activity generated in ex vivo tissue by high intensity focused ultrasound [ J]. Ultrasound in Medicine and Biology,2010,36(8): 1327- 1344.
  • 10C. R. Hill, J. C. Bamber, Gall R. ter Haar. Physical Principles of Medical Ultrasonics (Second Edition) [ M]. John Wiley & Sons, Ltd, 2004,378.

二级参考文献7

共引文献8

同被引文献30

  • 1Peng-Zhou Li, Shai-Hong Zhu, Wei He, Li-Yong Zhu, Sheng-Ping Liu, Yan Liu, Guo-Hui Wang, Fei Ye Department of General Surgery ,Department of Radiology, Third Xiangya Hospital, Central South University, Changsha 410013, China.High-intensity focused ultrasound treatment for patients with unresectable pancreatic cancer[J].Hepatobiliary & Pancreatic Diseases International,2012,11(6):655-660. 被引量:20
  • 2Tan To Cheung,Sheung Tat Fan,See Ching Chan,Kenneth SH Chok,Ferdinand SK Chu,Caroline R Jenkins,Regina CL Lo,James YY Fung,Albert CY Chan,William W Sharr,Simon HY Tsang,Wing Chiu Dai,Ronnie TP Poon,Chung Mau Lo.High-intensity focused ultrasound ablation:An effective bridging therapy for hepatocellular carcinoma patients[J].World Journal of Gastroenterology,2013,19(20):3083-3089. 被引量:23
  • 3McLaughlan J, Rivens I, Ter Haar G, et al. A study of bubble activity generated in ex vivo tissue by high intensity focused ultra- sound. Ultrasound Med Biol, 2010, 36(8) : 1327-1344.
  • 4Jensen CR, Cleveland RO, Coussios CC. Real-time temperature estimation and monitoring of HIFU ablation through a combined modeling and passive acoustic mapping approach. Phys Med Biol, 2013,58(17) : 5833-5850.
  • 5Yu T, Xu C. Hyperecho as the indicator of tissue necrosis during microbubble-assisted high intensity focused ultrasound: Sensitivi- ty, specificity and predictive value. Ultrasound Med Biol, 2008, 34(8) :1343-1347.
  • 6Nandlall SD, Jackson E, Coussios CC. Real-time passive acoustic monitoring of HIFU-induced tissue damage. Ultrasound Med Bi- ol, 2011,37(6):922-934.
  • 7Haar GT, Coussios C. High intensity focused ultrasound: Past, present and future. Int J Hyperthermia, 2007,23(2) :85-87.
  • 8Chen WS, Lafon C, Matula TJ, et al. Mechanisms of lesion for- mation in high intensity focused ultrasound therapy. Acoustics Research Letters Online, 2003,4(2) :41-46.
  • 9Lafon C, Khokhlova VA, Kaczkowski PJ, et al. Use of a bovine eye lens for observation of HIFU-induced lesions in real-time. Ul- trasound Med Biol, 2006,32(11) : 1731-1741.
  • 10Coussios CC, Farny CH, Haar GT, et al. Role of acoustic cavi- tation in the delivery and monitoring of cancer treatment by high- intensity focused ultrasound (HIFU). Int J Hyperthermia, 2007,23(2) : 105-120.

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部