摘要
空气中三氯苯胺用微孔滤膜采集 ,环已烷解吸 ,经 OV- 17和 OV- 2 10混合色谱柱分离 ,电子捕获检测器检测测定。对采集滤料、洗脱溶剂、采样流量进行了优选。方法的检出限为 0 .0 1mg/ L,当标准溶液浓度为 1~ 10 mg/ L 时 ,相对标准偏差为 4.5 %~ 2 .3% ,线性范围为 0 .0 0 5~ 30 mg/ L。采样效率为98.7%~ 10 0 .0 % ,样品在采样管中可稳定 15天以上。通过现场试验和验证试验证明该方法准确、灵敏、快速、简便 ,采样和运输携带方便 ,适用于空气中三氯苯胺的定点监测和个体监测。各项指标均符合“车间空气中有毒物质监测研究规范”和劳动卫生监测的要求。
Trichloroaniline in the air was collected with micropore filter membrane and desorbed with cyclohexane, separated with a column OV-17:OV-210 and determined by GC-ECD.Collection of filter, solution of desorping and flow-rate of sampling were selected. The detectable limit is 0.01mg/L. When the concentration of standard solution is 1~10mg/L, the relative standard deviation (RSD) is 4.5%~2.3%. There is a linear relation within the range of 0.005~30 mg/L. The sampling efficiency ratio is 98.7%~100%. The samplers were stable for at least 15 days. It is proved that this method is accurate, sensitive, rapid and easy for sampling and carrying. This method is suitable for the determination of Trichloroaniline in the air, for the detection of personal and of TWA.
出处
《江苏预防医学》
CAS
2000年第3期7-9,共3页
Jiangsu Journal of Preventive Medicine
关键词
三氯苯胺
微孔滤膜
空气
气相色谱法
Trichloroaniline, micropore filter membrane, air, gas chromatography