摘要 游泳场馆类建筑空调系统运行使用的特点与其他建筑不同。比较了广西体育中心游泳馆中地源热泵供应集中空调系统的冷热源侧设备搭配方案,分析了技术应用的可行性、空调系统运行节能性和经济性,提出游泳跳水馆空调水系统方案可采用2台相同水源热泵机组一次泵变流量的地源热泵系统。建议政府部门提供相关税收、补助等优惠政策,降低地源热泵空调系统的前期建造费用,从而缩短投资回收期。 The operation characteristics of air-conditioning system for swimming pool complex are different from the other buildings '. The matched scheme for devices at the hot and cold source side of central air-conditioning system with GSHP is compared for Guangxi Sports Center's swimming pool complex to analyze its technical feasibility, energy-efficiency and cost, proposing the primary ground source heat pump system with two same water source heat pumps of one variable flow is better for Swimming and Diving Hall's air-conditioning water system. It suggested that government departments emplement preferential policies of taxes and subsidies, etc. reducing the pre-construction costs of a ground source heat pump system, so as to shorten the payback period.