外界风对建筑中庭自然排烟的影响 被引量:1

The influence of external winds on Natural Smoke Exhaust in building atrium
下载PDF
导出
摘要 采用数值模拟的方法,分析了在自然排烟条件下,不同外界风对于中庭内烟气流动特性的影响。通过模拟得出:单侧外界风对于自然排烟烟气流动有明显影响,烟羽流倾斜角度随风速增加而增大,同一时刻相同高度的压力随风速增加而减小,温度大小相对于高度的变化率随风速增加而减小,较大的风速会造成排烟口流量相对于时间的变化率减小。 Based on the numerical simulation, the paper analyzes the influence of different external winds on smoke movement under natural ventilation. The results show that external winds from a single direction have obvious effects on smoke movement under natural ventilation. When the wind speed increases, the fire plum grows severely, the pressure in the same height at the same time turns lower, and the change rate of the gas temperature over time becomes smaller. The winds with high speed will make the flow through smoke vents descend faster.
作者 陈霄 谢妉
出处 《沈阳航空航天大学学报》 2013年第1期81-86,共6页 Journal of Shenyang Aerospace University
关键词 外界风 中庭 数值模拟 烟气流动 external winds atrium numerical simulation smoke movement
  • 相关文献

参考文献6

  • 1李引擎.性能化防火分析与设计[M].北京:化学工业出版社,2005.
  • 2陈颖,李思成,张靖岩,李开源.补风速度对中庭类建筑机械排烟效果的影响[J].暖通空调,2011,41(5):72-74. 被引量:13
  • 3Klote J H. An overview of atrium smoke management [ J ]. Fire Protection Engineering, 2000 ( 7 ) : 24 - 34.
  • 4MiIke J A. Smoke management for covered malls and atria [ J ]. Fire Technology, 1990,26 ( 3 ) : 223 - 243.
  • 5NFPA. NFPA92B Guide for smoke management sys- tems in malls, atria, and large areas [ S ]. USA : National Fire Protection Association ,2000.
  • 6胡冬冬,张学魁,王建英,李思成,魏东.大空间建筑火灾烟层界面高度的判定方法[J].暖通空调,2007,37(12):81-84. 被引量:3

二级参考文献29

  • 1中华人民共和国公安部.GB50045-95高层民用建筑设计防火规范(2005年版)[S].北京:中国计划出版社,2005
  • 2Tanaka T, Yamana T. Smoke control in large scale spaces(part 1) E.I-]. Fire Science and Technology, 1985,5(1) :31-40.
  • 3Milke J A. Smoke management for covered malls and atria[J]. Fire Technology, 1990,26 (3) : 223- 243.
  • 4Milke J A, Mowrer F W. A design algorithm for smoke management systems in atria and covered malls[R]. Maryland: University of Maryland College Park, 1993.
  • 5Hadjisophocleous G V, Lougheed G D. Experimental and numerical study of smoke conditions in an atrium with mechanical exhaust[J]. International Journal on Engineering Per{ormance-Based Fire Codes, 1999, 1 (3):183-187.
  • 6Klote J H. An overview of atrium smoke management [J].Fire Protection Engineering, 2000 (7):24-34.
  • 7Klote, J H. Method of predicting smoke movement in atria with application to smoke management[R]. Gaithersburg, Maryland. National Institute of Standards and Technology, 1994.
  • 8李思成,陈颖,陈兴,等.中庭机械排烟不同补风量效果数值模拟[C]//第五届消防性能化与消防工程研讨会.广州,20lO.
  • 9National Fire Protection Association. NFPA92B Guide for smoke management systems in malls, atria, and large areas[S]. Quincy, MA, US: The Standards Counci, 1995.
  • 10Kevin McGrattan. Fire Dynamics Simulator (Version 4) Technical Reference Guide [ M ]. Maryland: National Institute of Standards and Technology, 2005.