介绍了神华河北国华沧东发电有限责任公司首台国产600 MW抽汽凝汽式汽轮发电机组凝结水溶氧超标问题的原因分析,全面系统地揭示了凝结水溶氧超标问题的产生机理,给出了科学的治理对策。通过治理前后的数据对比进一步验证了凝结水溶氧超标综合治理方法的有效性,对同类型机组具有较为普遍的借鉴指导意义。
This paper mainly introduces the cause analysis to the problem that condensate water dissolved oxygen exceeded the standard in the domestic 600 MW extraction ation Co. Ltd. This paper comprehensively reveales the countermeasures. The management method of condensate condensing unit of Hebei Guohua Cangdong Power Gener- reason that the problem happened, and raises scientific water dissolved oxygen was further verified to be effective by data comparison. It has more universal guiding significance to the same type of generating unit
出处
《电力科学与工程》
2013年第2期72-78,共7页
Electric Power Science and Engineering
关键词
600
MW
溶氧
超标
治理
600 MW
dissolved oxygen
overstandard
management