期刊文献+

Investigation of the hydro-mechanical behaviour of fouled ballast 被引量:4

Investigation of the hydro-mechanical behaviour of fouled ballast
原文传递
导出
摘要 In this study,a fouled ballast taken from the site of Sénissiat,France,was investigated.For the hydraulic behaviour,a large-scale cell was developed allowing drainage and evaporation tests to be carried out with monitoring of both suction and volumetric water content at various positions of the sample.It was observed that the hydraulic conductivity of fouled ballast is decreasing with suction increase,as for common unsaturated soils.The effect of fines content was found to be negligible.For the mechanical behaviour,both monotonic and cyclic triaxial tests were carried out using a large-scale triaxial cell.Various water contents were considered.The results were interpreted in terms of shear strength and permanent axial strain.It appeared that the water content is an important factor to be accounted for since any increase of water content or degree of saturation significantly decreases the shear strength and increases the permanent strain.Constitutive modelling has been attempted based on the experimental results.The model in its current state is capable of describing the effects of stress level,cycle number and water content. In this study, a fouled ballast taken from the site of S6nissiat, France, was investigated. For the hydraulic behaviour, a large-scale cell was developed allowing drainage and evaporation tests to be carried out with monitoring of both suction and volu- metric water content at various positions of the sample. It was observed that the hydraulic conductivity of fouled ballast is decreasing with suction increase, as for common unsaturated soils. The effect of fines content was found to be negligible. For the mechanical behaviour, both monotonic and cyclic triaxial tests were carried out using a large-scale triaxial cell. Various water contents were considered. The results were interpreted in terms of shear strength and permanent axial strain. It appeared that the water content is an important factor to be accounted for since any increase of water content or degree of saturation significantly decreases the shear strength and increases the permanent strain. Constitutive modelling has been attempted based on the experimental results. The model in its current state is capable of describing the effects of stress level, cycle number and water content.
出处 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2013年第4期244-255,共12页 浙江大学学报(英文版)A辑(应用物理与工程)
基金 Project supported by the General Council of Ile-de-France and the Department of Seine-et-Marne,France
关键词 Fouled ballast Degree of saturation Hydraulic behaviour Mechanical behaviour Fines content Constitutive modelling Fouled ballast, Degree of saturation, Hydraulic behaviour, Mechanical behaviour, Fines content, Constitutivemodelling
  • 相关文献

参考文献49

  • 1AFNOR, 2004. EN 13286-7 Unbound and Hydraulically Bound Mixtures Part 7: Cyclic Load Triaxial Test for Unbound Mixtures.
  • 2Anderson, W.F., Fair, E, 2008. Behavior of railroad ballast under monotonic and cyclic loading. Journal of Geo- technical and Geoenvironmental Engineering, 134(3): 316-327. [doi:10.1061/(ASCE)1090-0241 (2008)134:3 (316)].
  • 3Barksdale, R.D., 1972. Laboratory Evaluation of Rutting in Base Course Materials. Proceedings of the Third Interna- tional Conference on Structural Design of Asphalt Pavement, 3:161 - 174.
  • 4Brooks, R.H., Corey, A.T., 1964. Hydraulic Properties of Porous Media. Hydrology Papers, No. 3, Colorado State University, Fort Collins, Colorado.
  • 5j, -7 Brown, S.F., 1974. Repeated load testing of a granular material. Journal of Geotechnical Engineering, 100(7):825-841.
  • 6Bruckler, L.B., Angulo-Jaramillo, P., Ruy, R., 2002. Testing an infiltration method for estimating soil hydraulic proper- ties in the laboratory. Soil Science Society of America Journal, 66(2):384-395. [doi:10.2136/sssaj2002.0384].
  • 7Chapuis, R.P., Masse, I., Maiinier, B., Aubertin, M., 2006. Essai de Drainage en Colonne Pour Obtenir les Propridtds non Saturdes de Mat6riaux Grossiers. Sea to Sky Geotechnique 59th Canadian Geotechnical Conference, Vancouver, Canada, p.905-912 (in French).
  • 8Cui, Y.J., Tang, A.M., Marcial, D., Terpereau, J.M., Marchad- ier, G., Boulay, X., 2007. Use of a differential pressure transducer for the monitoring of soil volume change in cyclic triaxial test on unsaturated soils. Geotechnieal Testing Journal, 30(3):227-233.
  • 9Cui, Y.J., Tang, A.M., Loiseau, C., Delage, P., 2008. Deter- mining the unsaturated hydraulic conductivity of a com- pacted sand-bentonite mixture under constant-volume and free-swell conditions. Physics and Chemistry of the Earth Parts A/B/C, 33:$462-$471. [doi:10.1016/j.pee. 2008.10.017].
  • 10Daniel, D.E., 1982. Measurement of hydraulic conductivity ofunsaturated soils with thermocouple psychrometers. Soil Science Society of America Journal, 46(6): 1125-1129. [doi:l 0.21361sssaj 1982.03615995004600060001 x].

同被引文献41

  • 1中华人民共和国铁道部.TBl0621-2009J971-2009高速铁路设计规范(试行)[S].北京:中国铁道出版社,2009.
  • 2KLUTE A. Laboratory measurement of hydraulic conductivity of unsaturated soils[M]//BLACK C A. Methods of Soil Analysis: Part 1. Madison: American Society of Agronomy, 253-261.
  • 3VAN GENUCHTEN M T. A closed-form equation for predicting the hydraulic conductivity of unsaturated soils[J]. Soil Science Society of American Journal, 1980, 44: 892-898.
  • 4FREDLUND D G XING A. Predicting the permeability function for unsaturated soils using the soil-water characteristic curve[J]. Canadian Geotechnical Journal, 1994, 31(3): 521-532.
  • 5LI X, ZHANG L M. Prediction of SWCC for coarse soils considering pore size changes[J]. Experimental Unsaturated Soil Mechanics, 2007, 112:401 - 412.
  • 6ZHANG L M, CHEN Q. Predicting bimodal soil-water characteristic curves[J]. Journal of Geotechnical and Geoenvironmental Engineering, 2005, 131(5): 666- 670.
  • 7DUONG T V, TRINH V N, CUI Y J, et al. Development of a large-scale infiltration column for studying the hydraulic conductivity of unsaturated fouled ballast[J]. Geotechnical Testing Journal, 2012, 36(1): 1 - 11.
  • 8TRANI L, INDRARATNA B. Assessment of subballlast filtration under cyclic loading[J]. Journal of Geoenvironmental Engineering, 2008, 136(11): 1519- 1528.
  • 9CHEN R P, CHEN Y, CHEN W, et al. Time domain reflectometry for water content measurement of municipal solid waste[J]. Environmental Engineering Science, 20 l 2, 29(6): 486- 493.
  • 10CHEN R P, CHEN Y M, XU W, et al. Measurement of electrical conductivity of pore water in saturated sandy soils using time dmain reflectometry (TDR) measure- ments[J]. Canadian Geotechnical Journal, 2010, 47: 197-206.