期刊文献+

电磁层析成像(EMT):正问题的理论分析 被引量:6

Electromagnetric Tomography (EMT):Theoretical Analysis of the Forward Problem
下载PDF
导出
摘要 基于感应原理的电磁层析成像 (EMT)是一种新颖的工业过程成像技术· 通过解析求解特定的两组分流成像正问题 ,导出了二维磁场分布的精确表达式 ,定量分析了传感器内部的物理机制和EMT技术的可检测性极限 ,建立了场灵敏度的直接数学表达式和灵敏度图· 在一定程度上 ,为传感器的定量设计 。 Inductance_based electromagnetic tomography (EMT) is a novel industrial process tomographic technique. Exact expressions of the magnetic field distribution in a two_dimensional object space were derived by analytically solving the forward problem for a particular two_component flow. The physical mechanisms within the sensor and the detectability limits of the EMT technique were quantitatively analyzed. Direct mathematical expressions for the field sensitivity and the sensitivity maps were established. To a certain extent, mathematical and theoretical bases are given for quantitative design of the sensor, detectability analysis of the EMT technique and image reconstruction of two_compontnt processes based on the linear back_projection algorithm.
出处 《应用数学和力学》 CSCD 北大核心 2000年第9期933-941,共9页 Applied Mathematics and Mechanics
基金 国家自然科学基金资助项目!(6 9574 0 2 1 598770 18)
关键词 正问题 CT 图像重建 电磁层析成像 EMT electrodynamics multi_phase flows tomography sensor technique electromagnetical measurement technique
  • 相关文献

参考文献4

  • 1Yu Z Z,IEEProcA,1998年,145卷,1期,20页
  • 2Yu Z Z,Electron Lett,1993年,29卷,7期,625页
  • 3Huang S M,IEEProcG,1992年,139卷,1期,83页
  • 4Xie C G,IEEProcG,1992年,139卷,1期,89页

同被引文献35

  • 1张闯,刘素贞,金亮,杨庆新.用于金属管材裂纹检测的涡流加载线圈设计[J].电工技术学报,2013,28(S2):172-175. 被引量:2
  • 2吴新杰,胡晟,付荣荣.基于COMSOL的电容层析成像系统灵敏度场的计算[J].辽宁大学学报(自然科学版),2011,38(3):193-196. 被引量:10
  • 3Peyton A J. An overview of electromagnetic induetance tomography : Description of three differcni systems [ J ]. Meas Sci Teehnol. 1996,7:261 -271.
  • 4Ma X, Peyton A,Higson S R,et al. Hardware and soflwan, design electromagnetic induction tomography(EMT) system for high con trast process applications [ J ]. Meas Sci Technol, 2006,17 : 111 - 118.
  • 5Korzhenevskii A V, Cherepenin V A. Magnetic induction tomo- graphy [ J ]. Journal of Communications Technology and Electro- nics, 1997,42 (4) :469 -474.
  • 6Korjenevsky A,Cherepenin V, Sapetsky S. Magmetic induction tomo- graphy :Experimental realization [ J ]. Physiol Meas, 2000,21 : 89 - 94.
  • 7Li Shijun, Qin Mingxin, Dong Xiuzhen. Magnetic induction tomo- graphy and the methods of its experimental realization [ J ]. Fo- reign Medical Science Biomedical Engineering,2002 (4) : 12 -16.
  • 8Doga G, Hennann S. lmaging artifacts in magnetic induction tomo- graphy caused by the structural incorrectness of the sensor mo- del[ J]. Meas Sci Technol,2011,22 :015502 -015512.
  • 9Vauhkonen M,Hamsch M,Igney C H. A measurement system and image reconstruction in magnetic induction tomography [ J ]. Phy- siol Mcas ,2008,29:445 -454.
  • 10雷彦,刘泽,徐志明,王志清.AD5933在电磁层析成像硬件系统中的应用[J].电子产品世界,2007,14(11):84-84. 被引量:1

引证文献6

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部