期刊文献+

高压跌落式重合闸熔断器在配电线路上的应用分析 被引量:1

Application and Analysis of High Voltage Drop-off Reclosing Fuse in Distribution Network
下载PDF
导出
摘要 目前,上海电网10kV架空配电线路上使用的PRW10-12C型高压跌落式重合闸熔断器,是新装备的一种线路熔断器,具有重合闸功能,因此提高了配电线路的安全运行水平和供电可用率。介绍了PRW10-12C型高压跌落式重合闸熔断器的结构、功能、运行状态、工作方式和维护注意事项;针对上海地区配电线路重合闸熔断器长期户外运行后出现的一些设备问题,进行了技术分析;提出了采用新技术、新工艺提高熔断器的瓷件质量以及进一步加强对熔断器在役线路的巡视和状态检测的建议,用以确保熔断器的正常和可靠工作。 PRW10- 12C high drop-reclosing fuse is a new type fuse with reclosing function, which is used in 10 kV overhead distribution lines of Shanghai Power Grid, and therefore improve the safe operation level of the distribution line and Power supply availability. Introduced the structure, function, operation status, work and maintenance precautions of a high drop-out PRWl0 - 12C type reclosing fuse; conducted technical analysis for some equipment problems from the reclosing fuse long-term outdoor running; put forward the recommendations including adoption of new technologies, new processes to improve the quality of fuses pieces of porcelain and the strengthening the in-service line inspections and checks in order to ensure the reliable operation of the fuse.
作者 宋敏
出处 《电力与能源》 2013年第2期201-203,共3页 Power & Energy
关键词 10 KV架空线路 高压跌落式重合闸熔断器 技术分析 对策 10 kV overhead distribution lines High voltage Drop-off reclosing fuse Technical analysis Solutions
  • 相关文献

参考文献2

二级参考文献5

  • 1刘振伶,耿林选,李建平,李洪涛.线路分散补偿电容器损坏原因简析及其改进措施[J].电力电容器,2006(4):45-48. 被引量:5
  • 2安顺合.电气设备安全运行与维修手册[M].北京:机械工业出版社,1994.
  • 3DL/T572-1995 电力变压器运行规程[S],1995.
  • 4GB/T11024-2001 电力电容器[S],2001.
  • 5张节容,徐国政,何维国,等.新型高压熔断器装置:中国,CN85100140[P].1986-08-27.

共引文献13

同被引文献4

引证文献1

二级引证文献7