期刊文献+

高频电源在300MW燃煤机组电除尘器节能提效改造中的应用 被引量:1

Application of high frequency power on energy-saving and effect-raising reformation of ESP in 300 MW units
下载PDF
导出
摘要 经国家对火电机组上大压小政策执行以来,300MW火电机组成为超标排放的主力机组,运行10年以上的该规模机组配套的电除尘器都面临着提效节能的改造。介绍了国电益阳发电有限责任公司2号300MW燃煤机组电除尘器的节能提效改造工程,提供了一种有针对性的改造实用方法。 Since the implementation of the small coal - fired units being stressed out policy,300 MW coal - fired u- nits has become the main units of exceeding the emission standard. The Electro - Static Precipitators which had been on operation for more than ten years are faced to improve the dust efficiency and energy - saving. The ESP energy - saving and efficiency improvement project of 300MW coal - fired units in Guodian Yiyang power limited liability company is introduced. It provides a practical method for modification.
出处 《电力科技与环保》 2013年第2期48-51,共4页 Electric Power Technology and Environmental Protection
关键词 电除尘器 高频电源 节能 工程管理 Electro - Static Precipitator high frequency power enery - saving energeering management
  • 相关文献

参考文献7

二级参考文献6

  • 1怀特H.J.工业电收尘[M].王成汉译,北京:冶金工业出版社,1984.
  • 2怀特HJ 王成汉译.工业电收尘[M].北京:冶金工业出版社,1984..
  • 3胡志光.电除尘器运行及维护[M].北京:中国电力出版社,2006.
  • 4李依琼,徐颞,卢泽锋.静电除尘器电源控制系统设计[C]//第十一届全国电除尘学术会议论文集.2005.
  • 5OPC Foundation. OPC data access custom interface specification [ R ]. Version 2.05A.2002.
  • 6MODBUS-IDA. MODBUS application protocol specification [R]. V1.1a, 2004.

共引文献10

同被引文献8

引证文献1

二级引证文献6