摘要
宁夏红寺堡扬水工程新庄集二泵站的24SA-18型离心泵在运行过程中,经常出现轴承发热、烧损及振动等故障,经过认真分析研究,发现原装水泵结构存在严重缺陷,在很大程度上影响了泵的安全运行。通过对水泵转子进行结构改造,弥补了原装水泵的结构缺陷,解决了影响运行的故障因素。
ANingxia GongSiBao pumping engineering xinzhuang set two pumping station 24 sa - 18 type centrifugal pump in the operation process, often appear bearing fever, loss and vibration failure, after careful analysis, we found that the original water pump structure have serious defect, to a great extent, affects the safe operation of pump. Through the pump rotor structure transformation, to make up for the original water pump structure defect, solve the influence of operation failure factors.
关键词
离心泵
轴承损坏
原因分析
故障处理
centrifugal pump
bearing damage
cause analysis
fault processing