期刊文献+

微波强化絮凝焦化生化出水的技术研究

Technology Research on Microwave Flocculating Coking Effluent
下载PDF
导出
摘要 以昆钢焦化生化出水为原水样,利用正交分析法对微波强化PAc絮凝处理进行实验,确定在微波功率800W,助溶剂PAM0.1mg/L,絮凝剂PAc500mg/L时,pH=7,微波反应60s,COD的去除率为30.98%,pH=9,微波时间30s,浊度的去除率为75.93%,与单一絮凝相比,COD、浊度的去除率分别提高了5%和18%左右,从而证明微波有助于提高絮凝效果。 Kungang coking effluent in raw water, PAC flocculation experiment, identified in the by mi orthogonal analysis method, the microwave enhanced erowave flocculant PAC 500 mg/L, pH=7, 60 s microwave reaction, power of 800 W, cosolvent PAM 0.1 mg/L, the removal rate of COD is 30.98%, pH=9, microwave time 30 s, turbidity removal rate was 75.93%, compared with a single flocculation, COD, turbidity removal rate were increased by 5% and effect of flocculation 18%, which proves that microwave helps to improve the
作者 刘缘缘 胡永
出处 《昆钢科技》 2012年第6期25-27,37,共4页
关键词 微波 焦化生化出水 絮凝技术 microwave coking effluent coagulation technology