摘要
通过在河北沽源和饶阳地区建立的40 m深试验孔,进行了长期(>1年)定时(1次/天)的浅层地温观测,分析研究了浅层地温场的特征,并确定了恒温层参数,沽源地区的恒温层深度约为24 m,温度约为5.6℃;饶阳地区的恒温层深度约为18 m,温度约为14.7℃。
Some records were made for shallow geothermal temperatures of Guyuan and Raoyang in Hebei Province through test drilling,with the depth of the dill hole reaching 40 meters.the observation period lasted for more than one year and the authors recorded the data once a day.Based on previous work,the authors made an analysis of the hallow geothermal field characteristics and determined the relevant parameters of the stratosphere: the stratosphere depth at Guyuan is 24 m and the temperature is about 5.6 ℃,whereas the stratosphere depth at Raoyang is 18 meters and the temperature is 14.7 ℃ accordingly.
出处
《物探与化探》
CAS
CSCD
2013年第2期237-241,共5页
Geophysical and Geochemical Exploration
基金
地质大调查项目(1212010916037)
关键词
沽源
饶阳
浅层地温场
恒温层
Guyuan
Raoyang
shallow geothermal field
constant temperature zone