摘要
以某电厂凝结水精处理系统无凝结水补水箱的情况为例,对机组启动和正常运行2个阶段精处理系统的运行情况进行了分析,给出了具体的处理措施,供采用类似运行方式时参考。
Taking the condensate polishing system without condensate make-up water tank of a power plant as example,the operational aspects of the condensate polishing system in processes of start-up and normal operation of the unit were analyzed.Some concrete treatment measures were given,which can be used as reference for other units operating in similar mode.
出处
《华电技术》
CAS
2013年第3期8-10,37,共4页
HUADIAN TECHNOLOGY
关键词
火电厂
凝汽器
凝结水补水箱
凝结水精处理
运行方式
thermal power plant
steam condenser
condensate make-up water tank
condensate polishing
operation mode