期刊文献+

傅立叶OCT对不同年龄正常人群角膜厚度的测量研究 被引量:3

Corneal thickness measurements obtained with Fourier-domain optical coherence tomography in different age groups of healthy subjects
下载PDF
导出
摘要 目的:研究傅立叶域光学相干断层成像系统(Fourier-domain optical coherence tomography,FD-OCT)测量不同年龄人群角膜厚度正常值。方法:选取健康受试者210例420眼,分为3组,青年组(18~40岁)70例140眼;中年组(41~60岁)70例140眼;老年组(≥61岁)70例140眼。用傅立叶OCT检测受试者双眼角膜中心区、内环区和外环区角膜厚度及平均角膜厚度。结果:通过FD-OCT测量的不同区域角膜厚度最薄处位于角膜中心区,平均厚度527.19±1.72μm;最厚处在外环上方,平均厚度582.42±2.50μm;左右眼不同区域间角膜厚度差异没有统计学意义(P>0.05)。通过FD-OCT测量的平均角膜厚度在三个不同年龄组间具有很好的一致性及相关性(右眼:青年组-中年组:r=0.949,中年组-老年组:r=0.924,青年组-老年组:r=0.981;左眼:青年组-中年组:r=0.996,中年组-老年组:r=0.901,青年组-老年组:r=0.876)。结论:采用FD-OCT前节功能测量角膜厚度具有可重复性、可信性、方便性,可以更好地代表实际上的角膜厚度。 AIM: To study normal value of corneal thickness in healthy subjects in different age groups with Fourier- domain optical coherence tomography (FD-OCT). METHODS:Total 420 eyes of 210 healthy volunteers were analyzed. These were divided into three groups: young group (YG, n=70, 140 eyes, 18 to 40 years old), medium group(MG, n= 70, 140 eyes, 41 to 60 years old), old group(OG, n=70, 140 eyes, more 61 years old). Corneal thickness in central zone and inner-ring and outer-ring zones were measured by using FD-OCT. RESULTS: The thinnest zone was 527. 19 ± 1. 72μm in central cornea zone, and the thickest zone was 582.42±2. 501μm in superior in outer zone. Differences of corneal thickness were not significant in different measured zones (P〉0.05). Average values of corneal thickness made by FD-OCT was better consistent and highly correlated for three groups (right eye: YG-MG: r=0.949, MG-OG: r= 0.924,YG-OG: r=0.981, left eye: YG-MG: r=0.996, MG-OG: r=0.901, YG-OG: r=0.876). CONCLUSION: Measurement of cornea thickness by FD-OCT is more reproducible, reliable and convenient, and may better represent actual cornea thickness.
出处 《国际眼科杂志》 CAS 2013年第4期674-676,共3页 International Eye Science
关键词 FD—OCT 角膜厚度 不同区域 Fourier- domain optical coherence tomography corneal thickness different zones
  • 相关文献

参考文献4

  • 1Vollmer L, Sowka J, Pizzimenti J, et al. Central corneal thickness measurements obtained with anterior segment spectral domain optical coherence tomography compared to ultrasound pachymetry in healthy subjects. Optometry 2012 ;83 ( 5 ) : 167-172.
  • 2Zhou SY, Wang CX, Cai XY, et al. Optical Coherence Tomography and Ultrasound Biomicroscopy Imaging of Opaque Corneas. Cornea 2013 ; 32(4) : e25-30.
  • 3Hong JP, Nam SM, Kim TI, et al. Reliability of RTVue, Visante, and slit-lamp adapted ultrasonic pachymetry for central corneal thickness measurement. Yonsei Med J 2012 ;53(3 ) : 634-641.
  • 4庞辰久,李舒茵,牛超,李金,丁行振,王丽娅.四种方法测量近视眼角膜中央厚度结果比较研究[J].中国实用眼科杂志,2010,28(7):717-720. 被引量:3

二级参考文献13

  • 1Doughty MJ,Zaman ML.Human corneal thickness and its impact on intraocular pressure measures:a review and meta-analysis approach[J].Surv Ophthalmol,2000,44:367-180.
  • 2Cheng H,Bates AK,Wool L,et al.Positive correlation of corneal thickness and endothelial cell loss.Serial measurements after cataract surgery[J].Arch Ophthalmol,1988,106:920-922.
  • 3Rainer G,Findl O,Petternel V,et al.Central corneal thickness measurements with partial coherence interferometry,ultrasound,and the Orbscan system[J].Ophthalmology,2004,111:875-879.
  • 4Cheng ACK,Ran SK,Tang E,et al.Pachymetry assessment with Orbscan Ⅱin postoperative patients with myopic LASIK[J].J Refract Surg,2006,22:363-366.
  • 5Prisant O,Calderon N,Chastang P,et al.Relaibility of pachymetric measurements using Orbccan after excimer refractive surgery[J].Ophthalmology,2003,110:511-515.
  • 6Buehl W,Stojnac D,Sacu S,et al.Comparison of three methods of measuring corneal thickness and anterior chamber depth[J].Am J Ophthalmol,2006,141:7-12.
  • 7Spadea L,Giammaria D,Genova LD,et al.Comparison of optical low coherence refractometry and ultrasound pachymetry in the measurement of central corneal thickness before and after photorefractive keratectomy[J].J Refract Surg,2007,23:661-666.
  • 8Reinstein DZ,Couch DG,Archer T.Direct residual stromal thickness measurement for assessing suitability for LASIK enhancement by Artemis 3D very high-frequency digital ultrasound arcscanning[J].J Cataract Refract Surg,2006,32:1870-1876.
  • 9Prakash G,Agarwal A,Jacob S,et al.Comparison of fourier-domain and time-domain optical coherence tomography for assessment of corneal thickness and intersession repeatability[J].Am J Ophthalmol,2009,148:282-290.
  • 10Thomas J,Wang JH,Rollins AM,at al.Comparison of corneal thickness measured with optical coherence tomography,ultrasonic pachymetry,and scanning slit method[J].J Refract Surg.2006,22:671-678.

共引文献2

同被引文献39

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部