期刊文献+

用电化学方法测试动脉模型壁面剪应力 被引量:3

A Study on the Wall Shear Stress of Artery Model by Using Electrochemical Measuring Technique
下载PDF
导出
摘要 应用电化学方法 ,对动脉模型 T形分叉部位流场壁面剪应力进行测试研究。测试了对于现有理论分析和数值计算都比较困难的高雷诺数 ( RE=1 0 0 0 - 2 0 0 0 )流动流场的壁面剪应力 ,并且对若干不同雷诺数及不同支管分流情况进行了系列测试。通过实验发现 ,此部位同时存在高剪应力区和低剪应力区 ,确定了它们的位置和剪应力的大小。系列测试还显示 :随着雷诺数的变化 ,无量纲剪应力有一定的变化 ;而当支管分流变化时 ,无量纲剪应力的变化很明显。 In this paper, we attempt to study the wall shear stress in the flow field of a T bifurcation section of an artery model by using an electrochemical measuring technique. We measure the wall shear stresses in the case of relatively high Reynolds numbers (Re=1000 2000) which are difficult to obtain through theoretical analyses and numerical calculations. We conduct systematic measurements of wall shear stresses for different Reynolds numbers and different flow ratios. According to the experiments, it is found that there exists both high and low shear stress regions and the locations of these regions, and the values of wall shear stresses are determined. It is shown from a series of tests that the dimensionless relative values of wall shear stresses change a little with the Reynolds numbers, but change substantially with the flow ratios.
作者 王山山 邱玲
机构地区 河海大学
出处 《应用力学学报》 CAS CSCD 北大核心 2000年第2期44-50,共7页 Chinese Journal of Applied Mechanics
关键词 动脉模型 T型分叉管 壁面剪应力 电化学方法 arterial model, T bifurcation section, wall shear stress, measurement, electrochemical technique.
  • 相关文献

参考文献7

  • 1D.J.Patel R.N.Vnishncw.基础血流动力学及其在疾病过程中的作用[M].成都:成都科技大学出版社,1984..
  • 2李获.电化学原理[M].北京:北京航空航天大学出版社,1989..
  • 3蒲国刚,电分析化学,1993年
  • 4Xu Xiaoyun,Proceedings of Beijing satellile symposium of the eighth international congress,1992年,402页
  • 5刘惠枝,边界层理论,1991年
  • 6李获,电化学原理,1989年
  • 7冯元桢,生物力学,1983年

共引文献3

同被引文献17

  • 1Mori Koji,Saito Takashi.Effects of stent structure on stent flexibility measurements[J].Annals of Biomedical Engineering,2005,33(6):733-742.
  • 2Narracott A J,Hose D R.Measurement of the symmetry of in vitro stent expansion:a stereo-photogrammetric approach[J].Journal of Medical Engineering & Technology,2003,27(2):59-70.
  • 3Chua S N D,Macdonald B J,Hashmi M S J.Finite-element simulation of slotted tube (stent) with the presence of plague and artery by balloon expansion[J].Materials Processing Technology,2004,155-156(1/2/3):1772-1779.
  • 4Natarajan S,Mokhtarzadeh-Dehghan M R.A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries[J].Medical Engineering & Physics,2000,22(8):555-566.
  • 5Benard N,Coisne D,Perrault R.Experimental study of blood laminar flow through a stented artery[C]//Proceedings of the 23rd Ammual EMBS International Conference.Piscataway,NJ,USA,2001:83-85.
  • 6Walsh P W,Chin-Quee S,Moore Jr J E.Flow changes in the aorta associated with the deployment of a AAA stent graft[J].Medical Engineering & Physics,2003,25(4):299-307.
  • 7倪中华,顾兴中,易红,等.微孔结构血管支架:中国,ZL 200510040936.8[P].2005-12-21.
  • 8Braunwald E.Heart disease:a textbook of cardiovascular medicine[M].北京:人民卫生出版社,1999:26-30.
  • 9Lutz R J,Cannon J N,Bischoff K B,et al.Wall shear stress distribution in a model canine artery during steady flow[J].Circulation Research,1977,41(3):391-399.
  • 10Mao Z,Hanratty T J.Application of an inverse mass transfer method to the measurement of turbulent fluctuation in the velocity gradient at the wall[J].Experiments in Fluids,1991,11(1):65-73.