摘要 某发电厂带式输送机中部采制样装置为CYJ型。由于装置流程、结构设计不合理,使用中存在煤样采制代表性差的问题。电厂针对装置的机械、电气设备和系统保护进行了改造,改造后的技术参数、设计特点及性能检验指标均达到国家标准和行业标准要求,具备机械化、标准化采制样能力,可为采制样机械设备的制造者和使用者提供参考。 The CYJ type sampling device is installed in the middle of the beh eonveynr ala power plant. Because of the unreasonable process control and structure design nf the device, the coal samples are not representative. Some improvements on the mechanical and electrical equipment as well as the system protection of the device are made. After such modifications, the technical benchmark, design characteristies and performance testing indices of the deviee all meet the related natinnal standard and industrial standard. Being capable of sampling mechanically and normatively, it can also prnvide the referenee tot the manufacturers and the users.
出处 《中国电力》 CSCD 北大核心 2013年第3期88-90,共3页 Electric Power
关键词 火电机组 皮带中部 采制样装置 改进 thermal power unit the middle part of a belt sampling device improvement
  • 相关文献

参考文献6

  • 1李小江.发电用煤的质量要求和验收的精细化管理[J].燃料纵横,20lO(1):4-7.
  • 2李小江,方文沐,李智愚,等.DL/T747-2001《发电用煤机械化采样制样装置性能验收导则》制定说明[J].电力标准化与汁繁,2003(3):11一15.
  • 3曹长武.电力用煤采制化技术及其应用[M].北京:中国电力出版社,2002.
  • 4GB/T19494.1-2004煤炭机械化采样第1部分:采样方法[S].2004.
  • 5GB/T19494-3-2004煤炭机械化采样第3部分:精密度测定和偏倚试验[S].2004.
  • 6张双武.基于发热量和硫分的燃煤发电成本分析[J].中国电力,2012,45(9):94-97. 被引量:8