期刊文献+

X射线荧光光谱法测定轻烧白云石中氧化钙、氧化镁、二氧化硅和磷的含量 被引量:3

Determination of CaO,MgO,SiO_2 and P in Light-burnt Dolomite by XRF
下载PDF
导出
摘要 建立了X射线荧光光谱法测定轻烧白云石中氧化钙、氧化镁、二氧化硅、磷的方法。试样以四硼酸锂做熔剂、溴化铵做脱模剂制备玻璃熔片,以标准物质和高纯碳酸钙、高纯氧化镁制备标准样片做校正曲线,应用基本参数法进行校正回归,试样测定结果的相对标准偏差(n=10)RSD在0.20%~3.00%之间。用化学法同时进行比对试验,两种方法的测定结果相符,满足轻烧白云石的检测需求。 An analysis method for determining CaO, MgO, SiO2 and P in light-burnt dolomite using X-ray fluorescence spectrometer (XRF) was established. Glass fuse was prepared with lithium tetraborate as the flux and ammonium bromide as the mold spray; and calibration curve was drawn using standard sample pieces made with standard material and high-purity calcium carbonate and magnesium oxide; while basic parameters were used to make calibration regression. The relative standard deviation (n= 10) RSD of the test result was in the range of 0.2 %-3.00%. Comparison test by chemical method produced the same result, proving that the XRF method can meet the analysis requirement of light-burnt dolomite.
出处 《安徽冶金》 2013年第1期38-39,42,共3页 Anhui Metallurgy
关键词 X射线荧光光谱法 轻烧白云石 熔融 相对标准偏差 XRF light-burnt dolomite melt RSD
  • 相关文献

参考文献2

二级参考文献4

  • 1谢忠信,等.X射线光谱分忻[M].北京:科学出版社,1982,254-255
  • 2吉昂,陶光仪,卓尚军,等.X-射线荧光光谱仪分析技术[M].北京:科学出版社,2002.111-115.
  • 3刘珍.化验员分析读本[M].北京:化学工业出版社,2004.306-308.
  • 4GB/T3286.1-1998,石灰石、白云石化学分析方法[S].

共引文献24

同被引文献606

引证文献3

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部