期刊文献+

降低珠江电厂#3炉末级再热器壁温超温次数

Reduce the number of overheat times of #3 furnace last stage reheater wall in Zhujiang Power Plant
下载PDF
导出
摘要 珠江电厂#3炉末级再热器壁温半年时间内超温达58次(以发生超温报警计算次数),平均每月9.7次。长期多频次超温容易造成锅炉再热器管屏发生金属疲劳,蠕变加速,管材寿命下降,严重时甚至诱发爆管停炉事故,极大的威胁着机组运行安全,降低炉末级再热器壁温势在必行。 There are 58 times of overtemperature in Zhujiang Power Plant #3 furnace last stage reheater wall (calculate the number of over-temperature alarm)in half a year, with an average of 9.7 times per month.Long-term muhi-frequency overtemperature is likely to cause metal fatigue and creep acceleration of the boiler reheater tube screen, decreasing life expectancy,even inducing severe burst pipe and shutdown accident, threaten the operation safety greatly.So,reducing the furnace last stage reheater wall temperature is imperative.
作者 张清平
机构地区 广州珠江电厂
出处 《企业技术开发》 2013年第3期42-43,共2页 Technological Development of Enterprise
关键词 珠江电厂 炉末级再热器壁 超温 降温措施 Zhujiang Power Plant furnace last stage reheater wall overtemperature cooling measures
  • 相关文献

参考文献1

  • 1山西省电力工业局编.锅炉设备运行[M].北京:中国电力出版社,1997.

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部