生物力学等效软质材料弹性模量静态测试方法的分析与探讨 被引量:2

Analysis and Research on Static Test Methods of Elastic Modules of Biomechanical Equivalent Artificial Soft Materials
原文传递
导出
摘要 针对生物力学等效软质材料的特点,在对现有测试方法研究分析的基础上,提出一种适于软质材料的基于光栅尺和千分表的弹性模量测试方法,实现了软质材料等应变下的压缩测试,并设计了测量所需的微位移系统。通过对测试结果的分析,验证了上述方法的可行性。 This paper is based on the research and analysis of the existing related measuring methods, and aimed at the characteristics of equivalent artificial soft materials, and it also proposes a new adaptable test method to measure elastic modules. The modules are based on capacitive gate transducer and micrometer which suits for soft materials. Based on this proposed method, a micro feed mechanism has been designed. The same strain of soft materials under compress test was realized, and the feasibility of this method by analyzing the test results was testified.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2013年第2期316-319,共4页 Journal of Biomedical Engineering
基金 四川省应用基础研究基金资助项目(07JY029-083) 安徽建筑工业学院博士科研启动基金资助项目
关键词 软质仿真材料 静态测试系统 弹性模量 微位移装置 Artificial soft materials Static test system Elastic modules Micro feed mechanism
  • 相关文献

参考文献13

  • 1XU N,BO S, YUN G, et al. Dynamic tensile testing of Softmaterials[JU. Exp Mech. 2009, 49 : 451-458.
  • 2SONG B,CHEN W, GE Y, et al. Dynamic and quasi-staticcompressive response of porcine muscle[J], J Biomech, 2007,40(13): 2999-3005.
  • 3CHEN W. LU F. FREW D J, et al. Dynamic compression tes-ting o. soft materials[J]. J Appl Mech .2002,69: 214-223.
  • 4戢敏,雷经发,袁中凡.基于振动冲击响应法的生物力学等效仿真软质材料的力学性能测试与分析[J].四川大学学报(工程科学版),2011,43(5):240-246. 被引量:2
  • 5雷经发,陈爽,袁中凡.生物力学等效仿真软质材料超声测量方法的分析与研究[J].四川大学学报(工程科学版),2010,42(4):242-248. 被引量:2
  • 6SCHOCK R B,BRUNSKIJ B, COCHRAN G B. In vitro ex-periments on pressure sore biomechanicsj stresses and strainsin indented tissues[C]// ASME 1982 Advances in Bioengi-neering, New York, 1982: 88-91.
  • 7黄立独,汪勤悫,麦福达.皮肤层在钢印挤压作用下的生物力学研究[J].中国生物医学工程学报,1997,16(1):127-127. 被引量:5
  • 8YU W, LI Y B, ZHENG Y P,et al. Softness measurementsfor open-cell foam materials and human soft tissue[J]. MeasSci Technol, 2006,17(7), 1785-1791.
  • 9MOROMUGI S, KUMANO S, UEDA M, et al. A sensor tomeasure hardness of human tissue[C]//5th IEEE Conferenceon Sensors, Daegu:20061 388-391.
  • 10WILDER E A, GUO S, UN-GIBSON S, et al. Measuringthe modulus o. soft polymer networks via a buckling-basedmetrology[J]. Macromolecules. 2006,39(12) . 4138-4143.

二级参考文献54

共引文献31

同被引文献15

  • 1刘乐斌,应大君,陈卫军.脊柱生物力学测试研究进展[J].解剖与临床,2005,10(1):68-69. 被引量:4
  • 2兰俊,陈其昕,翟晓军,陈之青.腰椎间盘退变时椎间隙形态与腰椎曲度变化及其临床意义[J].中国临床解剖学杂志,2005,23(2):157-159. 被引量:23
  • 3刘耀升,陈其昕,廖胜辉,唐小君,李方财,吴浩波,余世策.腰椎L_4~L_5活动节段有限元模型的建立与验证[J].第二军医大学学报,2006,27(6):665-669. 被引量:26
  • 4黄立独,汪勤悫,麦福达.皮肤层在钢印挤压作用下的生物力学研究[J].中国生物医学工程学报,1997,16(1):127-127. 被引量:5
  • 5LU Y M,HUTTON W C,GHARPURAY V M.Can varia-tions in intervertebral disc height affect the mechanical func-tion of the disc?[J].Spine(Phila Pa 1976),1996, 21(19):2208-2216;discussion 2217.
  • 6KIM Y E,GOEL V K,WEINSTEIN J N,et al.Effect of disc degeneration at one level on the adjacent level in axial mode[J].Spine (Phila Pa 1976),1991,16(3):331-335.
  • 7KUMARESAN S,YOGANANDAN N,PINTAR F A,et al.Contribution of disc degeneration to osteophyte formation in the cervical spine:a biomechanical investigation[J],J Or-thop Res,2001,19(5):977-984.
  • 8JAYSON M I.Compression stresses in the posterior elements and pathologic Consequences[J].Spine(Phila Pa 1976),1983,8(3):338-339.
  • 9Ni Annaidha A, Bruyred K, Destradea M,et al. Charac- terization of the anisotropic mechanical properties of ex- cised human skin[J-]. J Mech Behav Biomed Mater, 2012 (5):139-148.
  • 10Gennisson J L, Baldeweck T, Tanter M. Assessment of e- lastic parameters of human skin using dynamic elastic graph [J ]. IEEE Transactions on Ultrasonics, Ferro-eleetries and Frequency Control, 2004,51 (8) : 980.

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部