期刊文献+

两种不同长度切口超声乳化白内障手术疗效分析 被引量:7

Outcomes of cataract surgeries with different incisions
下载PDF
导出
摘要 目的评价2.2 mm与2.8 mm两种角膜缘小切口超声乳化白内障手术对白内障硬核术后疗效的影响。方法将200例(200只眼)年龄相关性白内障患者,按照不同大小角膜缘切口随机分为2.2 mm与2.8 mm两组,行角膜缘小切口超声乳化白内障吸除联合折叠式人工晶状体植入术,比较两组术后视力、超声乳化时间、手术时间及并发症等情况。结果两组术后l周、1个月、3个月最佳视力及手术时间、III级核超声乳化时间两组差异无统计学意义(P>0.05)、并发症差异无统计学意义(P>0.05),2.8 mm组IV级核超声乳化时间显著短于2.2mm组(P<0.01)。结论在白内障超声乳化吸除联合折叠式人工晶状体植入术中,2.2 mm角膜缘切口与2.8mm角膜缘切口对白内障硬核处理术后疗效相同,均是一种安全有效的手术切口。 Objective To compare the outcomes of hard nucleus cataract surgeries using coaxial 2.2 mm small corneal limbus-incisien versus using conventional coaxial 2.8mm small incision. Methods A randomized study was con- ducted on 200 patients with age-related cataract. Coaxial 2.2 mm small-incision cataract surgery was pedormed in 109 cases ( 109 eyes) and coaxial 2.8 mm small-incision cataract surgery (91 eyes). Visual acuity, surgical complications, effective ultrasonic emulsification time and operation time were compared between the two groups. Results There was no significant difference ( P 〈0.05) in best corrected visual acuity,operation time, ultrasonic emulsification time for grade m nucleus, and surgical complications between the two groups at 1 week, 1 month and 3 months after surgery. However, the ultrasonic emulsification time for grade IV nucleus was significantly shorter in 2.8 mm incision group ( P 〈 0.05 ). Conclusion 2.2 mm incision is as safe and effective as 2.8 mm incision for cataract surgery.
出处 《临床眼科杂志》 2013年第2期132-134,共3页 Journal of Clinical Ophthalmology
关键词 超声乳化白内障吸除术 角膜缘切口 Phaceemulsification cataract surgery Corneal limbus-incision
  • 相关文献

参考文献4

二级参考文献30

  • 1Ernest P, Rhem M, McDermott M, et al. Phacoemulsiflcation conditions resulting in thermal wound injury. J Cataract Refract Surg, 2001, 27:1829-1839.
  • 2Fine IH, Packer M, Hoffman RS. New phacoemulsification technologies. J Cataract Refract Surg, 2002, 28:1054-1060.
  • 3Pereira AC, Porfirio F Jr, Freitas LL, et aL Ultrasound energy and endothelial cell loss with stop-and-chop and nuclear preslice phacoemulsification. J Cataract Refract Surg, 2006, 32: 1661- 1666.
  • 4Davison JA. Ultrasonic power reduction during phacoemulsitication using adjunctive NeoSoniX technology. J Cataract Refract Surg, 2005, 31 : 1015-1019.
  • 5Fine IH, Packer M, Hoffman RS. Power modulations in new phacoemulsification technology: improved outcomes. J Cataract Refract Surg, 2004, 30 : 1014-1019.
  • 6Gimbel HV, Sofinski SJ, Kurteeva K, et al. AdvanTec Legacy System and the NeoSoniX handpiece. Curr Opin Ophthalmol, 2003, 14:31-34.
  • 7Vasavada AR, Raj SM, Lee YC. NeoSoniX ultrasound versus ultrasound alone for phacoemulsification: randomized clinical trial. J Cataract Refract Surg, 2004, 30:2332-2335.
  • 8Jiraskova N, Rozsival P. Phacoemulsification parameters., series 20000 Legacy Versus Legacy with AdvanTec software and NeoSoniX handpiece. J Cataract Refract Surg, 2004, 30: 144- 148.
  • 9Sekundo W,Boker T,Fimmers R.Induced corneal astigmatism using anasymmetric corneoscleral tunnel and a large optic intraocular lens[J].JCataract Refract Surg,2000,26(1):79-82.
  • 10Cavallini GM,,Lugli N,,Campi L,,et al.Surgically induced astigmatism after manual extracapsular cataract extraction or after phacoemul-sification procedure[J].Eur J Ophthalmol,1996,6:257-263.

共引文献23

同被引文献70

引证文献7

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部