期刊文献+

^(99m)Tc-培普利欧霉素诊断肺肿瘤的价值^(99m)Tc-MIBI比较 被引量:1

The Clinical Value of ^(99m )Tc-Peplimycin in the Diagnosis of Lung Neoplasm ——Comparison with ^( 99m)Tc-MIBI
下载PDF
导出
摘要 目的 :评价99mTc -PPM平面显像诊断肺癌的临床价值。材料与方法 :2 8例经X线、CT证实肺肿瘤患者 ,其中 2 0例恶性 ,8例良性。注射99mTc -PPM后 5min、15min、30min、1h行平面显像 ,选延迟相图像以ROI法处理 ,计算T/NT ;并与99mTc -MIBI比较。结果 :8例良性肿瘤的99mTc -PPMT/NT值为 1.0 4± 0 .0 8;2 0例恶性肿瘤的T/NT值为 1.41± 0 .16。以T/NT值 1.2为标准 ,99mTc -PPM对肺癌诊断的灵敏度、特异性和准确度分别为 90 % (18/2 0 )、87.5 % (7/8)、89.3 % (2 5 /2 8) ;该结果与99mTc -MIBI相比无明显的差异。结论 :99mTc -PPM可用于鉴别肺肿瘤显像 。 Purpose:To evaluate the clinical value of 99m Tc-PPM (Peplomycin) planar imaging in the diagnosis of lung cancer. Materials and methods: 28 patients, suffering from 20 malignants and 8 benign lesions in lungs, were evaluated by chest X-ray and CT scan. Patients were given a 555MBq 99m Tc-PPM. Planar images were taken at 5min、15min、30min、1h and 2h after injection. ROIs were drawn over tumor and control site on control side. Ratio of T/NT was calculated on 30min image. Results: The ratio of T/NT in 8 benign lesions was 1.04±0.08. The ratio in 20 malignancy was 1.41±0.16. The sensitivity, specificity and accuracy of identifying malignant lesion was 90% (18/20)、87.5%(7/8)、89.3%(25/28) respectively for 99m Tc-PPM. There is no difference in diagnostic peformance between 99m Tc-PPM and 99m Tc-MIBI. Conclusion: 99m Tc-PPM is an useful imaging agents in differentiating malignant lung neoplasm from benign lesions.
出处 《中国医学影像学杂志》 CSCD 2000年第5期357-359,共3页 Chinese Journal of Medical Imaging
关键词 肺肿瘤 闪烁显像 锝9m-PPM 诊断 lung neoplasm 99m Tc-PPM 99m Tc-MIBI
  • 相关文献

参考文献1

二级参考文献1

  • 1潘文生,上海医学,1993年,16卷,621页

共引文献3

同被引文献13

  • 1Schlomo S, Einat ES, Meir C, et al. Clinical applicationsof gamma-detection probes: radioguided surgery. Eur J Nucl Med,1999, 26 (Suppl): S26-S35.
  • 2Arnold MW, Yong DC, Hitchcock CL, et al. Radioimmunoguided surgery in primary colorectal carcinoma: an intraoperative prognostic tool and adjuvant to traditional staging. Am J Surg,1995, 170: 315-318.
  • 3Fleshman JW, Conner JW, Neufeld DW, et al. Tumorlocalization and radioimmunoimaging with mixture of radioiodinedmonoclonal antibodies directed to different colon cancer associatedantigens. Nucl Med Biol, 1992, 19: 659-668.
  • 4Hayashi N, Arakawa H. Nagase H, et al. Genetic diagnosis identigies occult lymph node metastasis undetectable by thehistopathologic method. Cancer Res, 1994, 54: 3853-3856.
  • 5Muller S, Guth-Tougelidis B, Greutzig H, et al. Imagingof malignant tumors with Tc-99m-MIBI SPECT. J Nucl Med,1987, 28: 562.
  • 6Muller SP, Reiners C, Paas M, et al. Tc-99m MIBI andT1-201 uptake in bronchial carcinoma. J Nucl Med, 1989, 30:845.
  • 7Ernest KJ, Pauwels V, Ralph M, et al. The mechanism ofaccumulation of tumour-localising radiopharmaceuticals. Eur J NuclMed, 1998, 25: 277-305.
  • 8Carvalho PA, Chiu ML, Kronauge JF, et al. Subcellulardistribution and analysis of technetium-99m-MIBI in isolated perfused rat hearts. J Nucl Med, 1992, 33: 1516-1522.
  • 9Maffioli L, Steens J, Pauwels E, et al. Applications of99m-Tc-sestamibi in oncology. Tumori, 1996, 82: 12-21.
  • 10Piwnica-Worms D, Chiu ML, Budding M, et al. Functional imaging of multidrug-resistant P-glycoprotein with an organotechnetium complex. Cancer Res, 1993, 53: 977-984.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部