摘要 在水中硒含量的测定过程中,用铜-铁混合基体改进剂,可以减少化学干扰,以及灰化过程中的挥发损失,并提高灰化温度。同时,避免了常用的基体改进剂镍的污染及记忆效应,对硒的吸光度呈增感作用,提高测定灵敏度,减少背景干扰。该方法的加标回收率在95%~102%之间。 During the process of determining the content of water selenium, using copper-iron mixed matrix modifier, may reduce chemical interference and the volatilization loss of dissolven during ashing process,and ashing temperature can be enhanced. At the same time,avoid the contamination and memory effect of nickel being used as common matrix modifier, temperature curve of ashing, absorbancy of selenium assume intensifying sensibilization, sensitivity of test is improved, and reduce background interference. Add mark recovery rate is around 95 %-102 % by using that method.
作者 郎娜
出处 《食品研究与开发》 CAS 北大核心 2013年第4期87-89,共3页 Food Research and Development
关键词 基体改进剂 灰化温度 石墨炉原子吸收 selenium common matrix modifier iashing temperature graphite furnace atomic absorption
  • 相关文献

参考文献6

  • 1方荣.原子吸收光谱法在卫生检验中的应用[M].北京:北京大学出版社,2003:163-164.
  • 2孔祥瑞.必需微量元素营养、生理及临床意义[M].合肥:安徽科学技术出版社,2003:454-456.
  • 3蔡乾清,施文赵.分析实验室[M].贵阳:贵州人民出版社,2007:119-12l.
  • 4王悦华,华佩冬,杨英.光谱学与光谱分析[J].北京:中国医院药学杂志,2006,12(5):323-325.
  • 5国家环保总局.水和废水监测分析方法[M].北京:中国环境科学出版社,2002..
  • 6中华人民共和国卫生部.GB/T5009.93-2010食品安全国家标准食品中硒的测定[S].北京:中国标准出版社,2010:1-5.