摘要
基于锅炉汽水管变形状况,结合锅炉运行工况,从锅炉负荷、排污、热膨胀以及水质几大影响因素进行分析,并提出解决方案,为锅炉汽水管的安全运行提供经验基础。
Based on the deformation of the water cooled tube, integrated boiler operating conditions, the influencing factors including the load of the boiler, boiler blowdown, thermal expansion and water quality were analyzed. The solution was proposed to provide an empirical basis for the safe operation of the bolier water cooled tube.
出处
《锅炉制造》
2013年第3期32-33,37,共3页
Boiler Manufacturing
关键词
变形
传热
负荷
排污
deformation
heat transfer
the load of the boiler
boiler blowdown