发射光谱法测低合金钢中硅结果不确定度评定 被引量:2

Evaluate Uncertainties for Results of Determining Silicon in Low Alloy Steels with Spark Emission Spectroscopic Method
下载PDF
导出
摘要 用火花源原子发射光谱法测定低合金钢中的硅,并对测定结果的不确定度进行评定,通过的测定过程中的各种不确定度的分析,得到了测定结果的不确定度主要由测量的重复性、工作曲线拟合、高低标校正、标准样品的不确定度、基体不一致性引入的不确定度组成。最后给出了扩展不确定度。 In the article, it is introduced how to determine silicon in low alloy steels with the spark emission spectro- scopic method and evaluate the uncertainties of results. Through analyzing the various uncertainties in the determination, it was found that the uncertainties of results were mainly composed by the repeatability of determination, fitting of working curves, correction of high and low standards, uncertainties of standard samples and inconsistency of matrices. Finally, the ex- panded uncertainty was presented.
出处 《包钢科技》 2013年第2期81-83,共3页 Science & Technology of Baotou Steel
关键词 火花源发射光谱法 低合金钢 不确定度 评定 spark emission spectroscopic method low alloy steels silicon uncertainties evaluate
  • 相关文献

参考文献2

  • 1JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 2CSM01010105-2006,火花源发射光谱测量容错合金钢测量结果不确定评定规范[s].

共引文献778

同被引文献18

  • 1薛平,宋欢,邬郅祁,杜利君.原子吸收光谱法测量不确定度的评定与应用[J].理化检验(化学分册),2005,41(6):420-422. 被引量:13
  • 2国家质量技术监督局计量司.测量不确定度评定与表示指南[M].北京:中国计量出版社,2000.29-44.
  • 3中国合格评定国家认可委员会.CNAS-CL10:2012检测和校准实验室能力认可准则在化学检测领域的应用说明[M].
  • 4国家认证认可监督管理委员会.2015《检验检测机构资质认定评审准则》[M].
  • 5钢铁研究总院.GB4336-2002碳素钢和中低合金钢火花源原子发射光谱分析方法(常规法)[s].
  • 6中国合格评定国家认可委员会.CNAS-GL06化学分析中不确定度的评估指南[M].
  • 7全国钢标准化技术委员会.GB/T 223.4-2008钢铁及合金锰含量的测定电位滴定或可视滴定法[S].北京:中国标准出版社,2008.
  • 8冶金工业部钢铁研究总院.GB/T 223.12-1991钢铁及合金化学分析方法碳酸钠分离-二苯碳酰二肼光度法测定铬量[S].北京:中国标准出版社,1991.
  • 9全国钢标准化技术委员会.GB/T 223.26-2008钢铁及合金钼含量的测定硫氰酸盐分光光度法[S].北京:中国标准出版社,2008.
  • 10冶金工业部钢铁研究总院.GB/T 223.28-1989钢铁及合金化学分析方法α-安息香肟重量法测定钼量[S].北京:中国标准出版社,1989.

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部