摘要 麻醉机通气系统污染是全麻术后患者肺部感染的常见因素之一。与麻醉机相关的医源性交叉感染已经引起广大麻醉医生及相关人员的重视。了解两者间的相关性和预防措施,可以使患者得到最大程度的保护。细菌过滤器的使用、人工鼻(HMEF)等可降低由麻醉机所导致的医院感染和被细菌污染的几率,麻醉机清洗消毒技术的临床应用对减少麻醉中及术后的肺部感染、提高医疗质量将起到重要的作用。现就近几年来麻醉机通气系统的污染与全麻术后患者的肺部感染相关性的研究进展予以综述。 Ventilation system contamination of anesthesia machines is one of the common tactors of postoperauve putmonary infection in patients. Anesthesia machine related iatrogenic cross-infection has attracted the attention of the majority of anesthesiologists and relevant staffs. Understanding their correlation and preventive measures can provide the patients with the greatest degree of protection. The application of bacteria proof filter and HMEF can reduce the probability of anesthesia machine caused hospital infection and bacterial contamination. The clinical application of anesthesia machine cleaning and disinfection technology plays an important role in reducing intraoperative and postoperative pulmonary infection and improving medical quality. This paper summarizes the study progress of the correlation between the anesthesia machine ventilation system contamination and the lung infection after general anesthesia.
出处 《中国医药导报》 CAS 2013年第13期166-168,共3页 China Medical Herald
基金 广西壮族自治区医疗卫生重点科研课题(编号重2011111)
关键词 麻醉机 通气系统 消毒 交叉感染 肺炎 Anesthesia machine Ventilation system Disinfection Cross-infection Pneumonia
  • 相关文献

参考文献24

  • 1Craven DE,Goularte TA,Make BJ. Contaminated condensate in me- chanical ventilator circuits. A risk factor for nosoeomial pneumonia? [J]. Am Rev Respir Dis, 1984,129(4):625-628.
  • 2Rathgeber J,Kietzmann D,Mergeryan H,et al. Prevention of patient bacterial contamination of anaesthesia-circle-systems: a clinical study of the contamination risk and performance of different heat and moisture exchangers with eleetret filter (HMEF)[J]. Eur J Anaesthe- siol, 1997,14(4) :368-373.
  • 3余丽华,刘世莲,罗明英.麻醉相关因素与下呼吸道医院感染的研究[J].中国消毒学杂志,2008,25(6):663-664. 被引量:11
  • 4De Castro Arai LA,Azevedo RB. Contamination of Anesthesia circuits by Pathogens [J]. Revista Brasileira de Anestesiologia,2011,61 ( 1 ) :50- 59.
  • 5高晓东,胡必杰,王文娟,任金兰,崔扬文,沈燕,周晴.上海市10所医院麻醉机内部管路污染情况及消毒方法探讨[J].中华医院感染学杂志,2010,20(12):1726-1727. 被引量:46
  • 6Germain JM ,Carbonne A,Thiers V ,et al. Patient-to-patient trans- mission of hepatitis C virus through the use of muhidose vials during general anesthesia [J]. Infection Control and Hospital Epidemiology, 2005,26 ( 9 ) : 789-792.
  • 7Helling TS,Van WC,Krantz S,et al. The value of clinical judgment in the diagnosis of nosocomial pneumonia [J]. Am J Surg, 1996, 171 (6) :570-575.
  • 8吴超,张亚英,沈黎,李春红.气管插管全麻术后医院感染危险因素研究[J].中华医院感染学杂志,2002,12(1):4-6. 被引量:100
  • 9肖永龙.无创性正压机械通气的临床应用[J].中国急救医学,1997,17(6):55-56. 被引量:9
  • 10Ping FC ,Ouhon JL,Smith JA ,et al. Bacterial filters-are they neces- sary on anaesthetic machines? [J]. Can Anaesth Soc J, 1979,26(5): 415-419.

二级参考文献28

  • 1林一雄,柯丽军,蔡建荣,方舒东.麻醉机回路内细菌过滤器检测报告[J].临床麻醉学杂志,2004,20(12):741-741. 被引量:11
  • 2栾湘宁,刘文荣,冯晓玲,胡晶.麻醉机螺纹管感染与消毒的探讨[J].中华护理杂志,1994,29(10):619-620. 被引量:9
  • 3吴励文,陈棉生,郑良杰,柯永坚,谢惠芳.全麻支气管插管与下呼吸道感染关系的调查[J].中华医院感染学杂志,2006,16(5):511-513. 被引量:26
  • 4The Association of Anaesthetists of Great Britain and Ireland[J]. Infection Control in Anaesthesia,2008,63:1027-1036.
  • 5Lynch JP 3rd. Hospital-acquired pneumonia. Chest, 2001,119(s): 373.
  • 6Teo DT, Lim TW. Transmission of tuberculosis from patient to healthcare workers in the anaesthesia context. Ann Acad Med Singapore. 2004, 33:95.
  • 7Vezina DP, Trepanier CA, Lessard MR, et al. Anesthesia breathing circuits protected by the DAR Barrierbac S breathing filter have a low bacterial contamination rate. Can J Anaesth,2001, 48: 748.
  • 8张海魁 尹少华.预防插管术后下呼吸道感染口咽部消毒作用观察[J].中华医院感染学杂志,2000,10(1):53-53.
  • 9Rebollo MH, Bernal JM, Llorca J, et al. Nosocomial infections in patients having cardiovascular operations: a multivariate analysis of risk factors[J]. J Thorac Cardiovasc Surg, 1996, 112(4): 908-13.
  • 10Zichmann B, Sablotzki A, Fussle R, et al. Perioperative microbiologic monitoring of tracheal aspirates as a predictor of pulmonary complications after cardiac operations[J]. J Thorac Cardiovasc Surg, 1996, 111(6): 1213.

共引文献201

同被引文献62

引证文献10

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部