摘要
介绍了反渗透系统运行指标标准化的意义,分析了修正系数法标准化的数学模型及其存在的问题,提出了膜元件与污染层双重动态特性的概念,明确了动态特性方法的计算过程及应用优势。
The significance of standardization for the operating indexes of reverse osmosis (RO) system was introduced. The standardized mathematical model of correction coefficient method and its issues were analyzed. The concepts of the membrane element and dual dynamic performance of the contamination layer were put forward. The calculation process of the dynamic performance and its application advantages were determined.
出处
《供水技术》
2013年第2期1-5,共5页
Water Technology
关键词
反渗透膜元件
标准运行指标
系统动态特性
RO membrane element
standard operating indicators
dynamic performance of the system