反渗透系统运行指标的标准化方法 被引量:2

Standardized methods for the operating indexes of reverse osmosis system
下载PDF
导出
摘要 介绍了反渗透系统运行指标标准化的意义,分析了修正系数法标准化的数学模型及其存在的问题,提出了膜元件与污染层双重动态特性的概念,明确了动态特性方法的计算过程及应用优势。 The significance of standardization for the operating indexes of reverse osmosis (RO) system was introduced. The standardized mathematical model of correction coefficient method and its issues were analyzed. The concepts of the membrane element and dual dynamic performance of the contamination layer were put forward. The calculation process of the dynamic performance and its application advantages were determined.
出处 《供水技术》 2013年第2期1-5,共5页 Water Technology
关键词 反渗透膜元件 标准运行指标 系统动态特性 RO membrane element standard operating indicators dynamic performance of the system
  • 相关文献

参考文献5

二级参考文献6

  • 1罗浩,靖大为.反渗透膜元件的运行数学模型[J].天津城市建设学院学报,2006,12(1):47-49. 被引量:7
  • 2邵刚.膜法水处理技术[M].北京:冶金工业出版社,2001..
  • 3邵刚.膜法水处理技术[M].北京:冶金工业出版社,2001.213-214.
  • 4MURIHEAD A, BEARDSLEY S,ABOUDIWAN J. Performance of the 12 000 m3/d seawater reverse osmosis desalination plant at jeddah [ J ]. Desalination, 1982,42 : 115-128.
  • 5AMJADZ[美].反渗透-膜技术·水化学和工业应用[M].殷琦,华耀祖,译.北京:化学工业出版社,1999.
  • 6李志西,杜双奎.实验优化设计与统计分析[M].北京:科学出版社,2010:167-176.

共引文献20