期刊文献+

A chemometric method to identify selective ion for resolution of overlapping gas chromatography-mass spectrometry signal

A chemometric method to identify selective ion for resolution of overlapping gas chromatography-mass spectrometry signal
原文传递
导出
摘要 A chemometric method to determine selective ion by using non-negative immune algorithm (NNIA) was proposed. In the method, the mutual projections of the chromatographic profiles at different m/z channel are calculated using NNIA. Suppose a GC-MS data with m retention time points and n mass channels, the projections of the GC-MS data onto a chromatographic profile at a mass channel will form a mass spectrum of ln vector. If the chromatographic profile at a selective mass channel is used, the extracted mass spectrum will be a correct one. Therefore, by comparing the extracted mass spectrum with a reference spectrum, the selective ion can be identified, and the corresponding chromatographic profile can be obtained at the same time. GC-MS data of 40-pesticide mixture was investigated by the method. The results show that both the mass spectral and the chromatographic information of the interested components can be extracted from the overlapping signals, except for the special cases of isomeric components with very similar mass spectra. A chemometric method to determine selective ion by using non-negative immune algorithm (NNIA) was proposed. In the method, the mutual projections of the chromatographic profiles at different m/z channel are calculated using NNIA. Suppose a GC-MS data with m retention time points and n mass channels, the projections of the GC-MS data onto a chromatographic profile at a mass channel will form a mass spectrum of 1 n vector. If the chromatographic profile at a selective mass channel is used, the extracted mass spectrum will be a correct one. Therefore, by comparing the extracted mass spectrum with a reference spectrum, the selective ion can be identified, and the corresponding chromatographic profile can be obtained at the same time. GC-MS data of 40-pesticide mixture was investigated by the method. The results show that both the mass spectral and the chromatographic information of the interested components can be extracted from the overlapping signals, except for the special cases of isomeric components with very similar mass spectra.
出处 《Science China Chemistry》 SCIE EI CAS 2013年第5期656-663,共8页 中国科学(化学英文版)
基金 financially supported by the National Natural Science Foundation of China (21175074)
关键词 gas chromatography-mass spectrometry selective ion detection immune algorithm CHEMOMETRICS resolution of overlapping peak 化学计量学方法 信号选择性 气相色谱 质谱 离子 GC-MS分析 定解 数据质量
  • 相关文献

二级参考文献2

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部