期刊文献+

基于STC12C5A16AD的电接点液位控制系统设计 被引量:1

Design of electric contact liquid level control system with STC12C5A16AD
下载PDF
导出
摘要 液位的平衡控制是锅炉安全运行的重要条件,介绍了以STC12C5A16AD单片机为核心的电接点液位控制系统。系统充分考虑到电极容易电解损坏的影响,采用了交变电压作为系统的检测信号,利用单片机的硬件和软件资源,实现了对容器液位的数值显示、模拟量输出、报警输出、RS-485输出、控制液位极限等功能。 The balance control of the liquid level is the important condition for safe operation of the boiler. In this paper, an electric contact liquid level control system by using STA12C5A16AD is intro- duced. By fully considering the influence of easily electrolytic damage of electrode, the alternating voltage is used as the system detection signal. With the use of single-chip hardware and software re- sources, it realizes the functions as flows: the numerical display of the level of a container, analog output, RS-485 output, liquid level limit control and so on.
出处 《辽宁科技大学学报》 CAS 2012年第6期609-613,共5页 Journal of University of Science and Technology Liaoning
关键词 STC12C5A16AD单片机 液位计 控制系统 STA12CSA16AD single chip microcomputer water level gauge control system
  • 相关文献

参考文献4

  • 1张玉择,王满稼.热工自动控制系统[M].北京:水利电力出版社,1985:46-48.
  • 2李庆常.数字电子技术基础[M].3版.北京:机械工业出版社,2010:125-216.
  • 3杨碧石,陈兵飞.ICL7660/7662变极性DC-DC变换器的原理与应用[J].国外电子元器件,2003(2):51-52. 被引量:4
  • 4谭浩强.C程序设计[M].4版.北京:清华大学出版社,2012:129-159.

共引文献13

同被引文献3

引证文献1

二级引证文献1