摘要 肾上腺疾病为腹部常见病,肾上腺多层螺旋CT扫描已成为肾上腺检查中不可或缺的检查手段,增强扫描在肾上腺疾病诊断中发挥着重要作用,然各种增强扫描方法及技术路线不尽相同,笔者通过阅读文献,归纳总结出肾上腺增强扫描的三种分析方法:常规动态增强扫描、时间-密度曲线分析法及CT灌注成像(CT perfu-sion imaging,CTPI)。现将各种增强CT扫描方法做一简要综述。 Adrenal gland diseases are common abdominal diseases. The multislice, spiral CT has become an indispensable means of examination in the adrenal gland check. Enhanced scan is playing a vital role in the diagnosis of adrenal gland diseases. There are various scanning methods and techniques concerning the enhanced scan. Through reading relevant documents, the author summarizes three major analytical methods for the enhanced scan of adrenal gland, i. e. regular dynamic contrast enhanced scan, time-density curve analysis and CT pe^rfusion imaging (CTPI). The author will make a brief review of the various methods of enhanced CT scan.
出处 《内蒙古医科大学学报》 2013年第01S期107-110,115,共5页 Journal of Inner Mongolia Medical University
基金 内蒙古财政厅科研项目(NC20080018) 内蒙古高等学校科学研究项目(NJZY07091)
关键词 肾上腺 计算机体层摄影 增强扫描 adrenal gland computed tomography enhanced scan
  • 相关文献

同被引文献20

  • 1王夕富,白人驹,王嵩,孙浩然,白旭,李亚军,王文红.肾上腺腺瘤和非腺瘤动态增强CT表现与血管生成相关性的初步研究[J].中华放射学杂志,2005,39(8):864-868. 被引量:36
  • 2王夕富,白人驹,王嵩,孙浩然,白旭,李亚军,王文红.肾上腺腺瘤和非腺瘤的动态增强CT检查[J].临床放射学杂志,2005,24(9):796-800. 被引量:28
  • 3朱传明,高菲,徐丽.肾上腺腺瘤的CT表现[J].内蒙古中医药,2006,25(6):77-78. 被引量:5
  • 4吕廷勇,陆涛,黄子荣,范光明.肾上腺肿瘤影像学诊断价值[J].贵州医药,2007,31(12):1142-1143. 被引量:1
  • 5Valentin J, International Commission on Radiation Protection. Man- aging patient dose in multi-detector computed tomography(MDCT) [J].Ann ICRP,2007,37:1-79,iii.
  • 6Marin D,Nelson RC, Schindera ST,et at.Low-tube-voltage, high- tube-current multide tector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative re- construction algorithm-initial clinical experience [J]. Radiology, 2010,254:145-153.
  • 7Heilbron BG, Leipsic J. Submillisievert coronary computed tomo- graghy angiograrhy using adaptive statistical iterative reconstruc- tion-a new reality[J]. Can J Cardiol,2010,26:35-36.
  • 8Hara AK,Paden RG,Sillva AC,et al.herative reconstruction tech- nique for reducing body radiation dose at CT: feasibility study [J].A JR,2009,193:764-771.
  • 9Laqmani A,Regier M,Veldhoen S,et al.Improved imaging quality and low radiation dose with hybrid iterative reeonstruetion with 80 kV CT puhnonary angiography [J].Eur J Radiol,2014,83:1962-1969.
  • 10Co SJ,Mayo J,Liang T.Itertive reconstructed ultra high pitch CT pul- monary angiography with cardiac bowtie-shaped filter in the acute setting: effect on dose and imaging quality[J]. Eur J Radiol,2013,82: 1571-1576.