摘要 目的:观察罗哌卡因联合利多卡因在腹膜透析置管手术中的疗效。方法:144例行腹膜透析置管手术的尿毒症患者随机分为3组。A组予2%利多卡因10 ml局部浸润麻醉;B组用0.894%盐酸罗哌卡因5 ml+2%利多卡因5 ml混合液行局部浸润麻醉;C组用0.894%盐酸罗哌卡因10 ml局部浸润麻醉。于麻醉后5,15,30,45,60,75 min,进行视觉模拟评分(VAS),术后评估镇痛质量及腹肌肌松质量,术中、术后记录患者生命体征及不良反应。结果:B、C两组镇痛评分在15 min后均低于A组,且两组镇痛质量及肌松质量优于A组(P<0.05)。B组不良反应发生率显著低于A、C两组(P<0.01)。结论:罗哌卡因联合利多卡因应用于腹膜透析置管手术起效快,镇痛效果好,且不良反应少。
出处 《中国药师》 CAS 2013年第4期592-593,共2页 China Pharmacist
基金 宜昌市科技与开发项目(编号:A2011-302-36)
  • 相关文献

参考文献9

  • 1王海燕.肾脏病学[M].第3版.北京:人民卫生出版社,2009.1414-1421.
  • 2王菊英,王小汤.吲哚美辛栓用于剖宫产术后镇痛的疗效分析[J].中国妇幼保健,2012,27(3):470-471. 被引量:5
  • 3Wildsmith JA, Brown DT, Paul D, et al. Structure-activity relationships in differential nerve block at high and low fre-quency stimulation [ J]. Br J Anaesth, 1989,63:444-452.
  • 4黄绍强.预防剖宫产脊麻后低血压的研究进展[J].临床麻醉学杂志,2009,25(1):88-90. 被引量:70
  • 5Beilin Y, Halpern S. Focused review: ropivacaine versus bupivacaine for epidural labor analgesia [ J ]. Anesth Analg, 2010, 111 ( 2 ) : 482- 487.
  • 6Mauch JY, Spielmann N, Hartnack S, et al. Electrocardiographic and haemodynamic alterations caused by three different test solutions of local anaesthetics to detect accidental intravascular injection in children [ J]. Br J Anaesth ,2012 , 108 (2) :283-289.
  • 7Karaman E, Gungor G, Alimoglu Y, et al. The effect of lidocaine, bupivacaine and ropivacaine in nasal packs on pain and hemorrhage after septoplasty [ J ]. Eur Arch Otorhinolaryngol, 2011, :268 ( 5 ) : 685- 689.
  • 8Nishiyama T. Comparison of the motor and sensory block by ropivacaine and bupivacaine in combination with lidocaine in interscalene block[ Jl. Med Arh,2012,66(5) :315-317.
  • 9岳云,吴新民,罗爱伦.摩根临床麻醉学[M].北京:人民卫生出版社,2007:814.

二级参考文献19

  • 1马凤梅.消炎痛栓治疗膀胱痉挛的临床分析[J].中国临床医生杂志,2006,34(3):35-35. 被引量:7
  • 2Bryson GL, Macneil R, Jeyaraj LM,et al. Small dose spinal bupivacaine for Cesarean delivery does not reduce hypotension but accelerates motor recovery. Can J Anaesth, 2007,54: 531- 537.
  • 3Van de Velde M, Van Schoubroeck D, Jani J,et al. Combined spinal-epidural anesthesia for cesarean delivery: dosedependent effects of hyperbaric bupivaeaine on maternal hemodynamics. Anesth Analg, 2006,103 : 187-190.
  • 4Hallworth SP, Fernando R, Columb MO, et al. The effect of posture and barieity on the spread of intrathecal bupivacaine for elective cesarean delivery. Anesth Analg, 2005, 100: 1159-1165.
  • 5Coppejans HC, Hendrickx E, Goossens J,et al. The sitting versus right lateral position during combined spinal-epidural anesthesia for cesarean delivery: block characteristics and severity of hypotension. Anesth Analg, 2006, 102 : 243-247.
  • 6Kundra P, Khanna S, Habeebullah S, et al. Manual displacement of the uterus during Caesarean section. Anaesthesia, 2007,62 : 460-465.
  • 7Simon L, Boulay G, Ziane AF,et al. Effect of injection rate on hypotension associated with spinal anesthesia for cesarean section. Int J Obstet AneSth, 2000,9 : 10-14.
  • 8Singh SI, Morley-Forster PK, Shamsah M,et al. Influence of injection rate of hyperbaric bupivacaine on spinal block in parturients:a randomized trial. Can J Anaesth, 2007, 54: 290- 295.
  • 9Hanss R, Bein B, Francksen H,et al. Heart rate variabilityguided prophylactic treatment of severe hypotension after subarachnoid block for elective cesarean delivery. Anesthesiology, 2006,104 : 635-643.
  • 10Erkinaro T, Makikallio K, Kavasmaa T, et al. Effects of ephedrine and phenylephrine on uterine and placental circulations and fetal outcome following fetal hypoxaemia and epidural-induced hypotension in a sheep model. Br J Anaesth, 2004,93: 825-832.

共引文献141

同被引文献106

引证文献12

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部