摘要
目的:对比配型前后血小板的输注效果,评估血小板抗体检测及相容性血小板输注的临床意义。方法:对血小板抗体筛查阳性患者进行血小板抗体配型,以出血症状改善情况、血小板计数增高指数(CCI)、血小板恢复百分率(PPR)为标准,对比相容性血小板输注的效果。结果:30例血小板输注无效患者的血小板抗体筛查阳性11例,11例血小板抗体阳性患者血小板交叉配型前后血小板输注有明显差异(P〈0.01),配型后输注的1h、24hCCI、PPR数值明显高于配型前输注的。结论:血小板抗体检测及配型可以为患者选择适用的血小板,提高单采血小板的输注效率,避免滥用血小板。
Objective : Our study aimed to assess the efficiency ofplatelets transfusion after cross-matched and evaluate the clinical significance of platelet antibody screening and compatibility of platelet transfusion for platelet refractoriness.Methods : The improving of haemorrhage symptom , corrected count increment(CCI)and percent platelet recovery (PPR) were as the standard, observe the efficiency of transfusion of PRE- and POST-platelets cross - matched .Results : There are 11 cases of platelet which antibody screening is positive from 30 cases of patients with invalid transfusion of single-donor platelet. There are significant differences in transfusion efficiency of PRE- and POST-platelets cross - matched .Conclusions : Platelet antibody screening and compatibility ofplatelet transfusion can improve the efficiency of single-donor platelet transfusion.
出处
《医学检验与临床》
2013年第1期35-37,共3页
Medical Laboratory Science and Clinics
关键词
血小板输注无效
血小板抗体检测
血小板配型
相容性血小板输注
Platelet refractoriness
Platelet antibody screening
Platelet cross - matched
Compatibility ofplatelet transfusion