Experimental study on themechanical properties of concrete for composite wall with internal thermal insulation layer
下载PDF
导出
摘要 内置保温层组合墙体是集结构承载和保温节能为一体的新型组合结构体系,结合其在浇筑工作面上进行混凝土湿筛分同时浇筑承重墙和保温层外混凝土保护层的施工工艺,制备了基准混凝土、湿筛分细石混凝土和二次混合混凝土的试件,采用水洗法测定了各种混凝土拌合物中粗骨料体积率及颗粒级配、水泥砂浆体积率及砂率,研究了这些参数变化与各种混凝土的拌合物工作性能及立方体抗压强度、轴心抗压强度和弹性模量之间的内在联系,为内置保温层组合墙体的混凝土湿筛浇筑工艺提供了科学依据。 The composite wall with internal thermal insulation layer is a new composite structure with the functions of the load bearing and the thermal insulation for energy conservation.In view of the cast-in-situ wet-sieving technology of concrete simultaneously construct- ing the reinforced concrete wall and the concrete cover outside the thermal insulation layer, the specimens were made of the original concrete,the fine-aggregate concrete passing the sieve and the second-mixed concrete.The volume percentage and grading of coarse aggregate, the volume percentage of cement mortar and the sand ratio of these kinds of concrete were measured by the washing method, which were analyzed to explore the inherence of the variation of workability of fresh concrete and cubic compressive strength, axial compressive strength and elastic modulus of hardened concrete.The result provided the scientific foundation for the cast-in-situ wet-sieving technology of concrete for the composite wall with internal thermal insulation layer.
出处 《混凝土》 CAS CSCD 北大核心 2013年第4期23-24,28,共3页 Concrete
基金 郑州市科技领军人才培育计划(096SYJH23105)
关键词 内置保温层组合墙体 混凝土 湿筛分浇筑工艺 拌合物工作性能 基本力学性能 composite wall with internal thermal insulation layer concrete cast-in-situ wet-sieving technology workability of fresh concrete basic mechanical property
  • 相关文献

参考文献8

  • 1LI Feng-lan, ZHAO Shan, YANG Su.Experimental study on linkage behavior of built-in insulation RCCW subjected to gravity load[J].Applied Mechanics and Materials, 2011 (71-78) : 197-200.
  • 2ZHAO Shun-bo,YANG Su,SONG Li-sha.Experimental study on thermal insulation properties of reinforced concrete composite wall[J]. Applied Mechanics and Materials, 2011 (99-100) :676-679.
  • 3ZHAO Shun-bo,LIANG Na,LIU Li-xin.Experimental study on mechanical properties of fine aggregate concrete made after wet-sieving coarse aggregate[J].Advance Materials Research, 2011 (168- 170) : 2200-2203.
  • 4ZHAO Shun-bo, ZHAO Shan, YANG Su.Experimental study on shrinkage of wet-sieving fine aggregate concrete made from ordinary concrete[J].dvance Materials Research,2011 (197-198) :915-918.
  • 5LI Xiao-ke,ZHAO Shan,SUN Li.Impermeability of wet-sieving fine aggregate concrete made from ordinary concrete[J].Advance Materials Research, 2011 (201-203) : 2883-2886.
  • 6ZHAO Shun-bo,LIANG Na,MA Xiao-lu.Experiment of carbonization for wet-sieving fine aggregate concrete made from ordinary concrete[J].Advance Materials Research,2011 (201-203) : 2887-2890.
  • 7GB/T50080-2002.普通混凝土拌合物性能试验方法标准[S].[S].,..
  • 8GB/T50081-2002.普通混凝土力学性能试验方法标准[S].[S].,..

共引文献170

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部