不同体位时FloTrac/Vigileo系统的临床应用分析 被引量:1

下载PDF
导出
摘要 临床上通常采用无创血压、心率、尿量评估机体血容量的状态,对于危重患者或某些手术患者可通过测定中心静脉压(CVP)、直接动脉压(ART)和肺动脉导管(PAC)压来评估。cVP系通过放置中心静脉导管,测量上、下腔静脉进入右心房处的压力,能静态反映右心前负荷,操作简单,但受右心泵血功能、循环血容量及体循环静脉系统血管紧张度的影响。ART测定用套管针经皮穿刺将外套管留在桡动脉里并连接压力换能器直接测压的一种方法,能即刻反映血压变化,但不能反映心脏功能,
出处 《上海医学》 CAS CSCD 北大核心 2013年第2期173-175,共3页 Shanghai Medical Journal
  • 相关文献

参考文献23

  • 1黄磊,张卫星,蔡文训,罗华,陈映群,张声.每搏量变异度预测严重感染和感染性休克患者容量反应性的价值[J].中华急诊医学杂志,2010,19(9):916-920. 被引量:38
  • 2CARRILLO LOPEZ A, SALA M F, SALGADO A R. The current role of the Swan-Ganz catheter[J].Med Intensiva, 2010, 34(3): 203-214.
  • 3SOLSONA DUR/AN J F, VAZQUEZ SANCHEZ A, NOLLA SALAS J. Swan-Ganz catheter and timing[J]. Med Intensiva, 2010, 34(7): 490.
  • 4ASENSI BONET N, OSSEYRAN SAMPER F, LORO REPRESA J M, et al. Multiple knotting of a swan-ganz catheter[J]. Rev Esp Cardiol, 2010, 63(7): 869-870.
  • 5BURREL M, REAL M I, BARRUFET M, et al. Pulmonary artery pseudoaneurysm after Swan-Ganz catheter placement: emholization with vascular plugs [J]. J Vase Interv Radiol, 2010, 21(4): 577-581.
  • 6ZUFFI A, BIONDI-ZOCCAI G, COLOMBO F. Swan-Ganz- induced pulmonary artery rupture: management with stent graft implantation[J]. Catheter Cardiovasc Interv, 2010, 76 (4) : 578-581.
  • 7CHATTERJEE K. The Swan-Ganz catheters: past, present, and future. A viewpoint[J]. Circulation, 2009, 119(1) :147-152.
  • 8CHATTI R, DE RUDNIKI S, MARQUE S, et al. Comparison of two versions of the Vigileo-FloTrac system (1. 03 and 1. 07) for stroke volume estimation: a multicentre, blinded comparison with oesophageal Doppler measurements[J]. Br J Anaesth, 2009, 102(4) : 463-469.
  • 9ZIMMERMANN A, STEINWENDNER J, HOFBAUER S, etal. The accuracy of the Vigileo/FloTrac system has been improved-follow-up after a software update: a blinded comparative study of 30 cardiosurgical patients [J ]. J Cardiothorac Vasc Anesth, 2009, 23(6): 929-931.
  • 10VASDEV S, CHAUHAN S, CHOUDHURY M, et al. Arterial pressure waveform derived cardiac output FloTrac/ Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output [J]. J ClinMonit Comput, 2012, 26(2): 115-120.

二级参考文献51

  • 1王如相.脉波指示剂连续心排血量(PiCCO)中的胸内血容量(ITBV)测定[J].生物医学工程与临床,2001,5(4):228-233. 被引量:27
  • 2颜彦,郭兴明,肖守中.心脏功能评价指标及其检测方法进展[J].医疗卫生装备,2005,26(1):21-23. 被引量:20
  • 3徐美丽.呼吸生理学[M].北京:人民卫生出版社,1992.192.
  • 4Lichtwarck-Aschoff M, Zeravik J, Pfeiffer U J. Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation. Intensive Care Med, 1992, 18: 142-147.
  • 5Pinsky M R. Functional hemodynamic monitoring. Intensive Care Med, 2002, 28.. 386-388.
  • 6Reuter D A, Bayerlein J, Goepfert M S, et al. Influence oI tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med, 2003, 29: 476-480.
  • 7Wiesenack C, Fiegl C, Keyser A, et al. Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anaesthesiol, 2005, 22: 658-665.
  • 8LorsomradeeS, Lorsomradee S, Cromheecke S, et al. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. J Cardiothorae Vase Anesth, 2007, 21: 636-643.
  • 9Felbinger T W, Goepfert M S, Goresch T, et al. Accuracy of pulse contour cardiac index measurements during changes of preload and aortic impedance. Anaesthesist, 2005, 54: 755-762.
  • 10Manecke G R Jr, Auger W R. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth, 2007, 21:3-7.

共引文献71

同被引文献5

引证文献1

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部