ARL-4460光电直读光谱仪分析钢中氮元素在唐钢的应用 被引量:2

Application of ARL-4460 Photoelectric Direct Reading Spectrometer in Nitrogen-in-Steel Analysis
下载PDF
导出
摘要 研究了火花源原子发射光谱法测定普碳、低合金钢中氮元素的方法。通过干扰元素的校正,改善了曲线拟合线性关系。自制控样类型校正,消除了系统误差。因熔融热导法对钢中氮的分析周期长、样品难加工、分析成本高的问题,应用ARL-4460光电直读光谱仪可以对转炉、精炼、中包试样中的氮元素快速分析。为公司一钢轧厂转炉一精炼一连铸流程的钢水氮元索的快速监测创造了条件,很好的满足炼钢工艺要求。 The paper makes a research on determining nitrogen in carbon and low alloy steel by spark source atomic emission spectrometry method. It improves curve fitting linear relationships by correcting interfering elements, and eliminates systematic errors by homemade control sample correction. As the analysis cycle is long by using fusion thermal conductivity method, the sample processing is difficult, and analysis cost is high, the ARL-4460 optical direct reading spectrometer is used to analyze the nitrogen in the converter, refining, and sample, providing reference for the rapid monitoring of nitrogen in the process from converter, refining to casting of steel rolling, and meeting the demand of steelmaking process.
作者 孙雪涛
出处 《价值工程》 2013年第13期317-318,共2页 Value Engineering
关键词 火花源原子发射光谱法 低合金钢 分析周期 spark source atomic emission spectrometry low-alloy steel analysis cycle
  • 相关文献

参考文献7

  • 1GB/T4336-2002碳素钢和中低合金钢火花源原子发射光谱分析方法[S].
  • 2史襄兴.实用连铸冶金技术[M].北京:冶金工业出版社,1998,191.
  • 3GB/T14265-1993金属材料中氢、氧、氮、碳和硫分析方法通则[S].
  • 4陶宝祺,王妮,陈杰,张为公.一个重要的实验现象--金属材料屈服平台处的泊桑比剧减和剧增现象[J].南京航空航天大学学报,1982.S2.
  • 5陈杰.缩短复合材料叶片制造周期的研究[J].玻璃纤维,2012(4):18-21. 被引量:1
  • 6鲁伟.电器控制盒[P].中国专利:CN302188834S,2012-11-21.
  • 7李降龙.自动检测仪[P].中国专利:CN302188823S,2012-11-21.

二级参考文献9