期刊文献+

热电厂泵汽蚀原因分析与防止措施 被引量:1

The causal analysis and prevention measures of cavitation erosion of water-feeding pump at a heat and power plant
下载PDF
导出
摘要 锅炉给水泵的正常运行是确保锅炉安全的第一步。而泵的汽蚀在生产运行中时有发生,不仅对泵本身危害极大,对整个热电厂安全运行也至关重要。本文将对给水泵汽蚀的原因进行分析,指出在给水泵进口压力最低点处,给水压力大于水温所对应的饱和压力,泵就不会产生汽蚀,并对防止给水泵汽蚀进行简要的说明。 The normal operation of boiler' s water - feeding pump is the hrst step tor ensunng satety. It not only harmed pump itself but also was important to whole heat and power plant,what cavitation erosion of pump occurred sometimes. The causal of cavitation erosion of water - feeding pump was analyzed, the resuks shown when the pres- sure of enter port was lowest and a pressure of feeding water was higher than saturation pressure of water, cavitation erosion of the pump would not occur, and prevention measures were explained briefly.
出处 《贵州化工》 2013年第2期60-61,共2页 Guizhou Chemical Industry
关键词 锅炉 给水泵 汽蚀 安全运行 boiler water - feeding pump cavitation erosion safe in operation
  • 相关文献

参考文献1

  • 1杨诗成,王喜魁.泵与风机[M].北京:中国电力出版社,2007.