摘要 首先建立三段式加热器变工况数学模型,并根据疏冷段传热系数的计算对加热器低水位运行情况进行了模拟;其次以某330 MW机组1#高压加热器为例,应用模型分别计算了正常水位运行端差、低水位运行时疏冷段换热状况及端差的变化;然后通过与试验数据的比较对计算结果进行验证,定量分析了加热器水位及负荷对端差的影响;最后重新设定0.14~0.15 m为安全水位,设定0.2 m为经济水位,比设计控制水位提高了近60 mm,可降低下端差2~3℃. A mathematical model of three-section heater for varying condition was established. The heater operation of low liquid level was simulated by this model with the calculation of the heat trans- fer coefficient of drain cooler. Taking #1 high pressure feedwater heater of a 330 MW steam turbine for example, the model was used to calculate the heater terminal temperature difference at regular liquid level, and the heat transfer condition of drain cooler and the terminal temperature difference at low liquid level. The calculation results were verified by the experimental data. The influence of heater liquid level and power load on terminal temperature difference was also quantitatively ana- lyzed. Finally, the security liquid level and the economic liquid level were reseted. The security liq- uid level was reseted as 0.14 to 0.15 m, and the economic liquid level was reseted as 0.2 m. The reseted liquid level is nearly 60 mm higher than the design control level, which can reduce the termi- nal temperature difference of the heater as 2 to 3 ℃.
出处 《东南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2012年第A02期314-319,共6页 Journal of Southeast University:Natural Science Edition
基金 国家自然科学基金资助项目(51176031)
关键词 加热器 水位 端差 传热系数 变工况 feedwater heater liquid level terminal temperature difference heat transfer coefficient varying condition
  • 相关文献

参考文献7

  • 1康松,杨建明,胥建群.汽轮机原理[M].北京:中国电力出版社,1999.
  • 2董卫国,徐则明.火电厂给水加热器的运行、维护和检修[M].北京:中国电力出版社,1997.
  • 3郭民臣,刘强,叶江明,陈爱萍.定功率下加热器端差对机组热经济性的影响[J].中国电机工程学报,2008,28(23):42-45. 被引量:23
  • 4Weber G E, Worek W M. Development of a method to evaluate the design performance of a feed water heater with a short drain cooler [ J ]. ASME Journal of Engi- neering for Gas Turbines and Power, 1994,116 ( 2 ) :434 -441.
  • 5吴慧英,帅志明.福斯特·惠勒高压给水加热器运行特性[J].中国电力,1997,30(8):59-62. 被引量:5
  • 6Gicquel R. Energy systems : a new approach to engineer- ing thermodynamics [ M ]. London : Taylor and Francis Group, 2012.
  • 7杨涛,石永锋,俞启云,等.江苏华电扬州发电有限公司300MW级亚临界机组综合提效技术示范工程可研性报告[R].杭州:华电电力科学研究院,2010.

二级参考文献18