期刊文献+

电感耦合等离子体质谱法同时测定工作场所空气中铅、镉、锰及其化合物 被引量:9

Determination of lead,cadmium and manganese in the air of workplace by ICP-MS
原文传递
导出
摘要 目的:探索并建立同时检测工作场所空气中铅、镉、锰及其化合物的电感耦合等离子体质谱分析法。方法:工作场所空气用微孔滤膜采集后,以压力罐消解法进行消化预处理,以电感耦合等离子体质谱法进行检测。结果:铅、镉、锰浓度为0μg/ml~0.50μg/ml时线性关系良好,相关系数r>0.999。铅、镉、锰的最低检出限分别为0.000019μg/ml、0.000022μg/ml、0.000012μg/ml。样品加标回收率铅、镉、锰分别是103.2%~105.2%、92.0%~99.0%、94.6%~104.5%,铅、镉、锰的相对标准偏差均<3%。结论:运用本法同时检测工作场所空气中铅、镉、锰及其化合物,具有良好的准确度和精密度,灵敏度高,检出限低,线性范围宽,元素之间的干扰少,方法高效可行。 Objective:To develop a method for detecting Lead,Cadmium,Manganese and their compounds in the air of workplace by ICP-MS.Methods: The samples were pretreated with pressure tank digestion method after sampling by microporous membrane.The Lead,Cadmium and Manganese were detected by ICP-MS.Results: The labeled recovery rate of Lead was between 103.2% and 105.2%.The detection limit was 0.000019 μg/ml and the correlation coefficient r was above 0.999.The labeled recovery rate of Cadmium was between 92.0% and 99.0%.The detection limit was 0.000022 μg/ml and the correlation coefficient r was above 0.999.The labeled recovery rate of Manganese was between 94.6% and 104.5%.The detection limit was 0.000012 μg/ml and the correlation coefficient r was above 0.999.The RSD of Lead,Cadmium and Manganese were all less than 3%.Conclusion: This method is accurate,precise and highly sensitive with low detection limit,wide linear range and less interference.It is applicable for detection of Lead,Cadmium,Manganese and their compounds in the air of workplace.
出处 《中国卫生检验杂志》 北大核心 2013年第4期842-844,共3页 Chinese Journal of Health Laboratory Technology
关键词 电感耦合等离子体质谱法 工作场所空气 ICP-MS The air of workplace Lead Cadmium Manganese
  • 相关文献

参考文献5

二级参考文献20

共引文献92

同被引文献92

引证文献9

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部