期刊文献+

Determination of trace level of perchlorate in Antarctic snow and ice by ion chromatography coupled with tandem mass spectrometry using an automated sample on-line preconcentration method 被引量:15

Determination of trace level of perchlorate in Antarctic snow and ice by ion chromatography coupled with tandem mass spectrometry using an automated sample on-line preconcentration method
原文传递
导出
摘要 A new ion chromatography coupled with tandem mass spectrometry (IC-ESI-MS/MS) method, with automated sampling and on-line preconcentration, has been developed for the determination of perchlorate in Antarctic snow and ice at low part-per-trillion (ng]L) levels. To the best of our lmowledge, this is the first time that an analytical method is used for the determination of perchlorate in Antarctic snow and ice. The IC-ESI-MS/MS instrumentation consisted of an ICS2000 ion chromatography (IC) system coupled to an API3200 electrospray tandem mass spectrometer (ESI-MS/MS). On-line preconcentration was realized through a six-port injector valve, a TAC-ULP1 concentrator column and an AS auto-sampler. Multiple reaction monitoring (MRM) mode was used to quantify the perch/orate anion. The transition of 35Cl]604- (m/z 98.9) into 3SC11603 (m[z 82.9) was monitored for quantifying the main analyte, and the transition of 37C11604 (m/z 100.9) into 37C1~603- (m]z 84.9) was monitored for examining a proper isotopic abundance ratio of 3sCl to 37C1, which was used as a confirmation tool. The limit of detection (LOD) and limit of quantitation (LOQ) for the method was 0.2 ng/ L and 0.5 ng/L, respectively. And this new method exhibited acceptable accuracy and precision for samples at ng/L levels. All the tested snow and ice samples were found to contain measurable amount of oerchlorate, ran^in~ from 10 nell to 340 nell.. A new ion chromatography coupled with tandem mass spectrometry (IC-ESI-MS/MS) method, with automated sampling and on-line preconcentration, has been developed for the determination of perchlorate in Antarctic snow and ice at low part-per-trillion (ng]L) levels. To the best of our lmowledge, this is the first time that an analytical method is used for the determination of perchlorate in Antarctic snow and ice. The IC-ESI-MS/MS instrumentation consisted of an ICS2000 ion chromatography (IC) system coupled to an API3200 electrospray tandem mass spectrometer (ESI-MS/MS). On-line preconcentration was realized through a six-port injector valve, a TAC-ULP1 concentrator column and an AS auto-sampler. Multiple reaction monitoring (MRM) mode was used to quantify the perch/orate anion. The transition of 35Cl]604- (m/z 98.9) into 3SC11603 (m[z 82.9) was monitored for quantifying the main analyte, and the transition of 37C11604 (m/z 100.9) into 37C1~603- (m]z 84.9) was monitored for examining a proper isotopic abundance ratio of 3sCl to 37C1, which was used as a confirmation tool. The limit of detection (LOD) and limit of quantitation (LOQ) for the method was 0.2 ng/ L and 0.5 ng/L, respectively. And this new method exhibited acceptable accuracy and precision for samples at ng/L levels. All the tested snow and ice samples were found to contain measurable amount of oerchlorate, ran^in~ from 10 nell to 340 nell..
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2013年第4期311-314,共4页 中国化学快报(英文版)
基金 financially supported by the National Natural Science Foundation of China(No.40906098) the Synthetic Investigation on the Environment in Polar Region (No.CHINARE 2013-02-02) the National Key Scientific Instrument and Equipment Development Project(No. 2012YQ09022907)
关键词 PerchlorateIon chromatographyTandem mass spectrometryAntarctic snow and ice PerchlorateIon chromatographyTandem mass spectrometryAntarctic snow and ice
  • 相关文献

参考文献3

二级参考文献133

  • 1Urbansky E T.Biorem.J.,1998,2:81-95
  • 2Motzer W E.Environ.Forensics,2001,2:301-311
  • 3Renner R.Environ.Sci.Teehnol.,2001,35:359A-360A
  • 4Orris G J,Harvey G J,Tsui D T,Eldridge J E.USGS Open-File Report 03-314
  • 5Dasgupta P K,Martinelango P K,Jackson W A,Anderson T A,Tian K,Tock R W,Rajagopalan S.Sci.Technol.,2005,39:1569-1575
  • 6Siglin J C,Mattie D R,Dodd D E,Hildebrandt P K,Baker W H.Toxicol.Sci.,2000,57:61-74
  • 7Urbansky E T.Crit.Rev.Anal.Chem.,2000,30:311-343
  • 8Collette T W,Williams T L,Urbansky E D,Magnuson M L,Hebert G N,Strauss S H.Analyst,2003,128:88-97
  • 9Jackson W A,Anderson T,Tock R,Lehman T,Ridley M.Final Report Submitted to Texas Commission on Environmental Quality.2003
  • 10Fisher J,Todd P,Mattie D,Godfrey D,Narayanan L,Yu K.Drug Chem.Toxicol.,2000,32(1):243-258

共引文献151

同被引文献148

引证文献15

二级引证文献90

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部