非晶硅平板探测器电子射野影像装置的剂量学特性研究
摘要
电子射野影像装置最初作为成像系统实现患者治疗时的精确摆位控制,是精确放疗的重要组成部分。电子射野影像装置按发展阶段分为荧光屏摄像机[1-2]、扫描矩阵电离室[3-4]和非晶硅平板探测器[5-7]。调强放疗的剂量验证必不可少,胶片作为最初验证设备因使用不便等原因已逐渐被数字矩阵设备(MapCHECK、唧等)所代替。本研究采用非一体化非晶硅平板探测器电子射野影像装置来研究其在剂量学方面的相关特性。
出处
《中华放射肿瘤学杂志》
CSCD
北大核心
2013年第3期258-259,共2页
Chinese Journal of Radiation Oncology
基金
江苏高校优势学科建设工程资助项目(苏政办发[2011]137号)
参考文献10
-
1Kroonwijk M,Pasma KL,Quint S,et al. In vivo dosimetry for prostate cancer patients using an electronic portal imaging device(EPID); demonstration of internal organ motion,Radiother Oncol,1998,49:125-132.
-
2Heijmen BJ,Pasma KL,Kroonwijk M,et al. Portal dose measurement in radiotherapy using an electronic portal imaging device(EPID).Phys Med Biol,1995,40:1943-1955.
-
3Boellaard R,Essers M,van Herk M,et al. A new method to obtain the midplane dose using portal in vivo dosimetry. Int J Radiat Oncol Biol Phys,1998,41:465-474.
-
4Boellaard R,van Herk M,Uiterwaal H,et al. First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose.Radiother Oncol,1998,47:303-312.
-
5McCurdy BM,Luchka K,Pistorius S. Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device. Med Phys,2001,28:911-924.
-
6Winkler P,Hefner A,Georg D. Dose-response characteristics of an amorphous silicon EPID. Med Phys,2005,32:3095-3105.
-
7McDermott LN,Louwe RJ,Sonke JJ,et al. Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device. Med Phys,2004,31:285-295.
-
8McDermott LN,Louwe RJ,Sonke JJ,et al. Comparison of ghosting effects for three commercial a-Si EPIDs. Med Phys,2006,33:2448-2451.
-
9Chen J,Chuang CF,Morin O,et al. Calibration of an amorphous-silicon fiat panel portal imager for exit-beam dosimetry,Med Phys,2006,33:584-594.
-
10Juste B,Miró R,Diez S,et al. Monte Carlo simulation of the iView GT portal imager dosimetry. Appl Radiat Isotopes,2010,68:922-925.
-
1彭俊玲.非晶硅平板探测器数字化X射线摄影在胸部摄影中的应用[J].实用医技杂志,2010,17(7):643-644. 被引量:1
-
2邱强.西门子KD—Ⅱ型直线加速器剂量学特性初探[J].医疗装备,2001,14(2):7-8.
-
3杨明,张新宽.TCT500S CT伪影故障维修1例[J].医疗设备信息,2005,20(1):76-76.
-
4郭良栋,娄从辉,孙进城,黄茹,吴强.数字化X线胸部摄影参数优化的探讨[J].实用放射学杂志,2011,27(12):1908-1910. 被引量:6
-
5张颖,陶建民,胡杰,张莹.高能医用电子束输出因子的剂量学特性[J].现代医学,2010,38(5):458-461. 被引量:3
-
6翟贺争,程金生,丁艳秋,郭朝辉,齐伟华,王军良,刘立明,刘雅,张红红.二维电离室矩阵探测器的光子剂量学性能测试[J].中华放射医学与防护杂志,2015,35(2):144-148. 被引量:6
-
7段勇.非晶硅和非晶硒平板探测器在胸部影像中的表现[J].中国医疗设备,2008,23(3):106-107. 被引量:2
-
8王骏,甘泉,陈新沛.DR组织均衡对照研究[J].放射学实践,2007,22(1):85-88. 被引量:6
-
9凌寿佳.非晶硒与非晶硅平板探测器在腰椎平片摄影中的比较[J].广西医科大学学报,2009,26(4):567-569. 被引量:2
-
10刘迎九,胡继光,许卫东.CT后处理技术对甲状腺的应用研究[J].中国地方病防治,2008,23(4):293-294. 被引量:1