摘要 针对静止无功补偿装置(SVC)水冷却系统通过单一的风机投切来实现降温控制出现的精度差、稳定性差等问题,引入电动三通阀对流经风机的水流比例进行模糊控制。根据专家理论知识和实践经验的总结给出其控制策略,利用Matlab仿真分析表明风机与电动三通阀相结合有良好的控制效果,有效避免风机频繁投切,增强水冷却系统稳定性,同时避免水温波动剧烈导致的阀组凝露现象。 Only using cooling fan to reduce the temperature of water may cause some problems with low accuracy and stability in SVC cooling system. Using electric three-way valve to control the proportion of water which goes through the cooling fan fuzzily can figure it out. This paper presented the control strategy based on specialized theories and practical experience. The result of studying with Matlab shows that the application of cooling fan and electric three-way valve gives a good control performance, effectively prevents the fans frequently switching and improve the stability of cooling system, avoid condensation caused by water temperature fluctuations.
出处 《仪表技术与传感器》 CSCD 北大核心 2013年第3期85-87,共3页 Instrument Technique and Sensor
关键词 水冷 模糊控制 电动三通阀 风机 稳定性 cooling fuzzy control three-way valve cooling fan stability
  • 相关文献

参考文献7

二级参考文献30

  • 1郭剑波,武守远,李国富,汤广福,荆平,周孝信,陈晓伦,杨玉林,彭夕岚,王劲武,李效珍.甘肃成碧220kV可控串补国产化示范工程研究[J].电网技术,2005,29(19):42-47. 被引量:52
  • 2柯赫震.硬件和软件结合提高微机保护抗干扰能力的措施[J].电气应用,2005,24(5):17-20. 被引量:5
  • 3孙振武,霍裕平,刘根成,李玉晓,李涛.Automatic Control System of Ion Electrostatic Accelerator and Anti-Interference Measures[J].Plasma Science and Technology,2007,9(1):101-105. 被引量:1
  • 4池田羲雄.实用热管技术[M].北京:化学工业出版社,1988.10-13.
  • 5张扬,蔡春伟,孙明健.S7-200PLC原理与应用系统设计[M].北京:机械工业出版社,2007.
  • 6西门子中国有限公司.深入浅出西门子S7-200[M].北京:北京航空航天大学出版社,2006.
  • 7国网运行有限公司.南桥站2007年06月23日极I内冷水3B分支流量传感器故障导致闭锁分析报告[R].北京:国网运行有限公司,2006.
  • 8王安全,等.±500 kV 葛南直流输电系统南桥换流站运行规程[R].上海:上海市电力公司超高压输变电公司,2009.
  • 9国网运行有限公司.灵宝站2008年2月8日LTT阀电抗器冷却水管脱落导致闭锁分析报告[R].北京:国网运行有限公司,2006.