期刊文献+

含Pt保护层对氧传感器性能的影响研究 被引量:2

Research on Influence of Protection Layer with Pt on Oxygen Sensor
下载PDF
导出
摘要 响应时间和使用寿命是氧传感器最重要的两个指标。依据电化学原理选用氧化锆和Pt做主要材料的保护层,使其成为催化三相界面载体和反应区。通过氧传感器特性曲线分析表明,新保护层减小扩散阻碍作用对电极性能的影响,从而提高氧传感器的反应速度和寿命。 Response time and the service life are the two most important indexes of oxygen sensor.The protective layer selected zirconia and Pt as main material based on the electrochemical principle,made it become catalytic three-phase interface carrier and the main reaction area,that reduced gas diffusion barrier effect on electrode performance caused by protective layer.Thereby it improves the reaction speed and the service life of the oxygen sensor.
出处 《仪表技术与传感器》 CSCD 北大核心 2013年第3期93-95,共3页 Instrument Technique and Sensor
关键词 氧传感器 电化学 三相界面 oxygen sensor electrochemical three-phase interface
  • 相关文献

参考文献8

  • 1RONALD K Jurgen.汽车电子手册.2版.鲁植雄,译.北京:电子工业出版社,2010:85 -97.
  • 2夏朝阳,卢旭晨,闫岩,王体壮,张志敏,杨素萍.保护层对汽车尾气氧传感器响应特性影响[J].传感器与微系统,2011,30(8):25-27. 被引量:3
  • 3J. MEGEL H,NEUMANN,WIEDENMAN H-M. Exhaust gas sensors forautomotive emission control. Solid State Lonics ,2002(152 -153) :783 — 800.
  • 4玛瑞克J,特拉汉H- P,苏左克,等.汽车传感器.左治江,译.北京:化学工业出版社,2004:131 -141.
  • 5PENG Z Y,LIUA M ,Balkob E. A new type of amperometric oxygensensor based on a mixed-conducting composite membrane. Sensor andactuators B,2001(75) :35 -40.
  • 6NAZARPOURA S,L6PEA - G6NDARBC,ZAMANIC C,et al. Modifi-cation of the oxygen diffusivity in limiting current oxygen sensors. Sen-sors and Actuators B ,2011 (155) : 489 -499.
  • 7IVERS-TIFFE’E E,HARDTLK H,MENESKLOUW,et al. Principles ofsolid state oxygen sensors for lean combustion gas control. Electrochim-ica,2001 (47):807 -814.
  • 8夏风,肖建中,罗志安,等.ZrO2氧传感器电极保护层的模拟.传感器技术学报,2004(2) :303 -305.

二级参考文献9

  • 1简家文,杨邦朝,张益康.交流阻抗谱测试技术在固体电解质氧传感器研究中的应用[J].功能材料,2004,35(4):464-466. 被引量:5
  • 2路顺,林健,张舜.ZrO_2氧传感器多孔保护层研究[J].玻璃与搪瓷,2006,34(5):7-10. 被引量:9
  • 3lnaba T, Saji K. Low temperature operation of thin-film limiting current type oxygen sensor using graded composition layer electrodes [ J ]. Sensor and Actuators B,2008,129:874.
  • 4Anderson J E, Graves Y B, Hysteresis effects with ZrO2 oxygen sensors exposed to non-equilibrium oxygen-hydrocarbon mixtures[ J ]. Journal of Applied Electrochemistry, 1983,13:395.
  • 5Badwal S P S, Bannister M J, Ciacchi F T. Response rate tech- niques for zirconia based Nernstian oxygen sensors [ J ]. Journal of Applied Electrochemistry,1988,18:608.
  • 6Barbueci A, Bozzo R, Cerisola G, et al. Characterisation of composite SOFC cathodes using electrochemical hnpedance spectros- copy-Analysis of Pt/YSZ and LSM/YSZ electrodes[ J ]. Electrochimiaca Acta ,2002,47:2183.
  • 7Yoon Sung Pil, Nam Suk Woo, Kim Seung-Goo, et al. Characteristics of cathodic polarization at Pt/YSZ interface without the effeel of electrode microstructure [ J ]. Journal of Power Sources, 2003, 115:27.
  • 8Gur E M,Raistrick I D, Huggins R A. AC admittance measure- ments on stabilized zirconia with porous platinum electrodes[ J ]. Solid State Ionics,1980,1:251.
  • 9夏风,肖建中,罗志安,冯江涛.ZrO_2氧传感器电极保护层的模拟[J].传感技术学报,2004,17(2):303-305. 被引量:8